Preliminary Data Sheet 3.0 Amp Glass Passivated
Sintered Rectifiers
Mechanical Dimensions
Description
JEDEC
D0-201AD
.285
.375
1.00 Min.
.050 typ.
.190
.210
Features
n LOWEST COST FOR GLASS SINTERED
CONSTRUCTION
n 3.0 AMP OPERATION @ TA = 55°C, WITH
NO THERMAL RUNAWAY
n LOWEST VF FOR GLASS SINTERED
CONSTRUCTION
n SINTERED GLASS CAVITY-FREE
JUNCTION
n TYPICAL IR < 100 nAmps
Electrical Characteristics @ 25oC.
Units
GPZ30A . . . 30M Series
Maximum Ratings
30A
30B
30D
30G
30J
30K
30M
Peak Repetitive Reverse Voltage...VRRM
RMS Reverse Voltage...VR(rms)
DC Blocking Voltage...VDC
Volts
Volts
Volts
50
35
50
100
70
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
100
1000
Amps
Amps
Average Forward Rectified Current...IF(av)
Current 3/8" Lead Length @ TA = 55°C
............................................. 3.0 ...............................................
............................................. 125 ...............................................
Non-Repetitive Peak Forward Surge Current...IFSM
8.3mS, ½ Sine Wave Superimposed on Rated Load
Volts
< ...... 1.1 ...... > < ............................. 1.0 ........................... >
............................................. 100 ...............................................
Forward Voltage @ 3.0A...VF
µAmps
Full Load Reverse Current...IR(av)
Full Cycle Average @ TA = 55°C
DC Reverse Current...IR(max)
@ Rated DC Blocking Voltage
T A = 25°C ............................................. 5.0 ...............................................
TA = 150°C ............................................. 200 ...............................................
µAmps
pF
............................................. 40 ...............................................
............................................. 15 ...............................................
............................................. 2.0 ...............................................
......................................... -65 to 175 ..........................................
Typical Junction Capacitance...CJ (Note 1)
Typical Thermal Resistance...RθJA (Note 2)
Typical Reverse Recovery Time...tRR (Note 3)
Operating & Storage Temperature Range...TJ, TSTRG
°C/W
µS
°C