5秒后页面跳转
GPM130 PDF预览

GPM130

更新时间: 2024-11-06 12:25:31
品牌 Logo 应用领域
SLPOWER /
页数 文件大小 规格书
2页 279K
描述
130 Watt Global Performance Switchers

GPM130 数据手册

 浏览型号GPM130的Datasheet PDF文件第2页 
GPC130 Commercial/GPM130 Medical  
130 Watt Global Performance Switchers  
FEATURES:  
Wide-range ac input 85-264 Vac  
2-year warranty  
Commercial Approved to UL1950, IEC950,  
EN60950 and CSA22.2-234 L3  
Medical Approved to UL2601-1, IEC601-1 and  
CSA22.2 No. 601  
Conducted EMI exceeds FCC Class B and CISPR 22  
Class B (Commercial models) and CISPR 11 Class B  
(Medical models)  
marked to LVD  
Power Fail  
SPECIFICATIONS:  
TTL- or CMOS-compatible output goes low (< 0.5V) 5 ms  
before output voltage drops more than 4% below nominal  
voltage upon loss of ac power.The signal is factory set to  
trip on 84 to 94Vac brown-out depending upon incoming line  
impedance and distortion. Other settings are available to the  
user through adjustment of built-in potentiometer.  
Ac Input  
85-264 Vac, 47-63 Hz single phase.  
Input Current  
Maximum input current at 120Vac, 60 Hz with full rated output  
load: 3.5 A  
Output Noise  
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode.  
Measured with noise probe directly across output terminals of  
the power supply.  
Hold-UpTime  
20 ms minimum from loss of ac input at full load, nominal line  
(115Vac).  
Transient Response  
Output Power  
100 W continuous, 165W peak;130W with 26 cfm air flow.Peak  
ratings are for 60 s maximum duration, 10% duty cycle. During  
peak load condition, output regulation may exceed total  
regulation limits.  
Main output500µSec typical response time for return to within  
0.5% of final value for a 50% load step change. i/t<0.2 A/µs.  
Maximum voltage deviation is 3.5%. Startup/shutdown overshoot  
less than 3%.  
Overload Protection  
Remote Sense  
Provided as a standard feature on output 1.  
Fully protected against short circuit and output overload. Short  
circuit protection is cycling type power limit on outputs 1 & 2;  
foldback type on outputs 3 & 4. Recovery after fault is automatic.  
See output ratings chart for additional notes or conditions.  
Voltage Adjustment  
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.  
Overvoltage Protection  
Main outputs: 124% ± 12% typical.  
Overload Protection  
Factory set to begin power limiting at approximately 170W.  
Efficiency  
EMI/EMC Compliance  
70% at full rated load, nominal input voltage, depending on model  
and load distribution.  
All models include built-in EMI filtering to meet the following  
emissions requirements:  
EMI SPECIFICATIONS  
COMPLIANCE LEVEL  
Turn-onTime  
Conducted Emissions GPC130 EN55022 Class B; FCC Class B  
Conducted Emissions GPM130 EN55022 Class B; FCC Class B  
Less than 1 second at 120Vac, 25°C (inversely proportional to  
input voltage and thermistor temperature).  
Static Discharge  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
Input Protection  
Internal ac fuse provided. Designed to blow only if a catastrophic  
failure occurs in the unit.  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
Commercial Leakage Current  
0.7 mA 254 Vac @ 60 Hz input.  
Inrush Current  
Inrush is limited by internal thermistors.Inrush at 240Vac under  
cold start conditions will not exceed 34 A.  
Commercial Safety  
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and  
EN60950. UL file #E135803 commercial; CSA #LR46516 all  
models.The output(s) are intended for safety earthed Signal  
Output and Intermediate Circuits only. All dc outputs are SELV  
under normal and single fault conditions.  
Temperature Coefficient  
0.03%/°C typical on all outputs.  
Thermal Shutdown  
Provided as a standard feature. Designed to protect unit from  
prolonged overtemperature.  
Medical Leakage Current  
35 µA 254 Vac @ 60 Hz input.  
Environmental  
Medical Safety  
Designed for 0 to 50°C operation at full rated output power;  
derate output current and total output power by 2.5% per °C  
above 50°C. See Environmental and Packaging Specifications  
on next page.  
Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL  
file E116994;CSA #LR46516.The output(s) are intended for  
safety earthed Signal Output and Intermediate Circuits only.The  
output(s) are not acceptable for patient connection without  
additional isolation.All dc outputs are SELV under normal and  
single fault conditions.  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
54  

与GPM130相关器件

型号 品牌 获取价格 描述 数据表
GPM130A SLPOWER

获取价格

130 Watt Global Performance Switchers
GPM130AG SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 130W,
GPM130B SLPOWER

获取价格

130 Watt Global Performance Switchers
GPM130C SLPOWER

获取价格

130 Watt Global Performance Switchers
GPM130D SLPOWER

获取价格

130 Watt Global Performance Switchers
GPM130DG SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 130W
GPM130E SLPOWER

获取价格

130 Watt Global Performance Switchers
GPM130EG SLPOWER

获取价格

AC-DC Regulated Power Supply Module, 130W,
GPM140 SLPOWER

获取价格

140 Watt Global Performance Switchers
GPM140-12 SLPOWER

获取价格

140 Watt Global Performance Switchers