GPFC110 Commercial
110 Watt Global Performance Switchers
110 WATT GLOBAL PERFORMANCE SWITCHERS
FEATURES:
• 3.1 watts/cu.in. power density
• Compact size (6.3” x 3.75” x 1.62”;
meets 1U height)
• Power factor corrected to IEC 1000-3-2 Class A
• Less than 300 μA leakage
• EMI compliance to CISPR 22, FCC Class B
• Approved to UL1950, IEC950 and
CSA 22.2 No. 950
• 2-year warranty
•
marked to LVD
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
EMI/EMC Compliance
All models include built-in EMI filtering to meet the EMC requirements below.
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
EMI SPECIFICATIONS
COMPLIANCE LEVEL
Maximum input current 2.3 A at 90 Vac, 60 Hz with full rated load. Input cur-
rent harmonic content meets the requirements of IEC1000-3-2.
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
EN55022 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A
Hold-up Time
25 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
110 W fan cooled, 75 W convection. Peak ratings are for 60 s maximum dura-
tion, 10% duty cycle.
Inrush Current
Total Regulation
Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold
start conditions. Limiting provided by internal thermistors.
Total regulation is the maximum deviation from the nominal voltage for all
steady-state loading conditions.
Fan Output
Overload Protection
An additional output, same as Vout, suitable for powering a dc fan is included in all
models. The output is protected by an internal resistor in the event of an overload.
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit. Recovery after fault is automatic.
Output Noise
Power Fail
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with
noise probe directly across output terminals of the power supply.
TTL or CMOS compatible output goes low (<0.5 V) 8 ms before output voltage
drops more than 4% below nominal voltage upon loss of ac power. The signal is
factory set to trip when input power can no longer sustain the output.
Transient Response
500 μs typical response time for return to within 0.5% of final value for a 50%
load step change, ∆i/∆ t< 0.2 A/μs. Maximum voltage deviation is 3.5%. Load
must not go below stated minimum.
Temperature Coefficient
0.03%/°C typical on all outputs.
Environmental
Remote Sense
Designed for 0 to 50°C operation at full rated output power; derate output current
and total output power by 2.5% per °C above 50°C. See Environmental and Pack-
aging Specifications on the next page.
Provided as a standard feature. Capable of compensating for 0.25 V total of
cabling losses in voltage. Open sense lead protection.
Overvoltage Protection
OVP crowbar reduces output voltage below nominal rating in less than 50 ms.
Commercial Safety Approvals
All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB
certificate available. Exceeds FCC and CISPR22 Class B conducted emissions
requirement
Voltage Adjustment: Main output 5%.
Input Protection
Internal ac fuse provided on all models. Fuse does not blow on overload or
short circuit—fuse blows only if catastrophic failure occurs in the unit.
All specifications are typical at nominal input, full load at 25OC unless otherwise stated