Special Encoders & Sensors
Sensing range 15°, 30°, 60°, 360°
CANopen / Profibus-DP
GNAMG
Features
– Inclination sensor / CANopen / Profibus
– Measuring range two-dimensional: 15°, 30° and 60°
– Measuring range one-dimensional: 360°
– Resolution: 0.001° to 1°
– Precision: ±0.1° to 0.5°
– Programmable parameters
– Protection IP 66
Optional
– Stainless steel
GNAMG with mounting plate 99 x 60 mm
Technical data - electrical ratings
Technical data - mechanical design
Voltage supply
10...30 VDC
Housing
Mounting plate with bus cover
Reverse polarity protection Yes
Dimensions mounting plate 99 x 60 x 5 mm
Protection DIN EN 60529 IP 66
Consumption w/o load
Initializing time (typ.)
Interfaces
≤100 mA (24 VDC)
250 ms after power on
Materials
Bus cover: zinc die-cast
Mounting plate: aluminium
CANopen, Profibus-DPV0
Rotary switch in bus cover
Operating temperature
-25...+85 °C
User address
-40...+85 °C (optional)
Measuring range
15°, 30°, 60° (two-dimensional)
360° (one-dimensional)
Relative humidity
Resistance
95 % non-condensing
DIN EN 60068-2-6
Resolution
Accuracy
0.001...1 ° (measuring range
15°)
0.01...1 ° (measuring range 30°)
0.01...1 ° (measuring range 60°)
0.1...1 ° (measuring range 360°)
Vibration 10 g, 16-2000 Hz
DIN EN 60068-2-27
Shock 200 g, 6 ms
Weight approx.
E-connection
250 g
Cable gland or connector M12
±0.1 ° (measuring range 15°)
±0.2 ° (measuring range 30°)
±0.5 ° (measuring range 60°)
±0.5 ° (measuring range 360°)
Build-up time max.
Measuring cycle
Code
0.5 s
10 Hz
Binary
Interference immunity
Emitted interference
DIN EN 61000-6-2
DIN EN 61000-6-4
Programmable
parameters
Resolution
Preset and offset
Moving average filter
Diagnostic function
Status indicator
Parameter error
DUO-LED integrated in bus
cover
Approval
UL approval / E63076
www.baumerivo.com
1