450-001
Qwik-Ty® Strain Relief - Connector Designator D
Direct Coupling (Straight)
Rotatable Coupling (45° and 90° Elbows)
450 D S 001 M 16 G
Product Series
Ground Lug (Omit for none)
Shell Size (Table I)
Finish (Table II)
CONNECTOR
DESIGNATOR
Connector Designator
D
Angle and Profile
A = 90
B = 45
Basic Part Number
S = Straight
A Thread
(Table I)
G
H
F
D
D
B (Table I)
E
(Table I)
(Table I)
J
STRAIGHT
DIRECT COUPLING
E
.140 (3.6) Dia (Typ.)
Use MS3367-1 Tie
Strap or Equivalent
Ground Lug
(Optional)
E
(Typical)
45°
90°
ROTATABLE COUPLING
ROTATABLE COUPLING
See inside back cover fold-out or pages 13 and 14 for Tables I and II.
TABLE III: DIMENSIONS
E
F
Max
G
Max
H
Max
Shell
Size
08
10
12
14
16
18
20
J
Max
Cable Entry
.275 (7.0) 1.400 (35.6) 1.850 (47.0) 1.240 (31.5)
.402 (10.2) 1.400 (35.6) 1.850 (47.0) 1.240 (31.5)
.516 (13.1) 1.400 (35.6) 1.850 (47.0) 1.240 (31.5)
.651 (16.5) 1.610 (40.9) 2.350 (59.7) 1.230 (31.2)
.766 (19.5) 1.610 (40.9) 2.350 (59.7) 1.230 (31.2)
.872 (22.1) 1.610 (40.9) 2.440 (62.0) 1.260 (32.0)
.997 (25.3) 1.680 (42.7) 2.510 (63.8) 1.260 (32.0)
1.125 (28.6) 1.680 (42.7) 2.510 (63.8) 1.260 (32.0)
1.247 (31.7) 1.770 (45.0) 2.650 (67.3) 1.260 (32.0)
.880 (22.4)
.940 (23.9)
1.000 (25.4)
1.320 (33.5)
1.380 (35.1)
1.460 (37.1)
1.510 (38.4)
1.560 (39.6)
1.630 (41.4)
22
24
1. Cable Entry is defined as the accommodation entry for the wire bundle or cable.
Dimensions are not intended for inspection criteria.
2. Metric dimensions (mm) are indicated in parentheses.
© 2005 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
Series 45 - Page 3