GBU8A ~ GBU8M
VOLTAGE 50V ~ 1000V
Elektronische Bauelemente
8.0 AMP Glass Passivated Bridge Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen-free.
LC-35
.874(22.2)
.860(21.8)
3.2*3.2
CHAMFER
.139(3.53)
.133(3.37)
.154(3.9)
.146(3.7)
.752(19.1)
.720(18.3)
FEATURES
.232(5.9)
.224(5.7)
n
n
n
n
Glass passivated die construction
Ideal for printed circuit board
.073(1.85)
.057(1.45)
_
~
High case dielectric strength of 1500VRMS
~
+
Plastic material has underwrites laboratory
flammability classification 94V-0
.100(2.54)
.085(2.16)
Max..138(3.5)
.022(.56)
n
n
n
n
Low reverse leakage current
Surge overload rating to 200A peak
Polarity: marked on body
.018(.46)
.080(2.03)
.065(1.65)
.047(1.2)
.035(0.9)
.106(2.7)
.091(2.3)
Mounting position: Any
.210 .210 .210
.190 .190 .190
(5.3) (5.3) (5.3)
(4.8) (4.8) (4.8)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25oC ambient temperature unless otherwise specified.
Resistive or inductive load, 60Hz,
For capacitive load, derate current by 20%.
GB
U8K
GBU8A
GBU8M
TYPE NUMBER
SYMBOL
GBU8B
GBU8D
GBU8G
GBU8J
UNITS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
VRRM
VRMS
VDC
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
V
V
V
Maximum DC Blocking Voltage
Maximum Average Forward (with heatsink Note2)
Rectified Current @ TC=100 (without heatsink)
Peak Forward Surge Current, 8.3 ms single
half Sine-wave superimposed
I(AV)
A
8.0
IFSM
200
A
on rated load (JEDEC method)
Maximum Forward Voltage at 2.0A
Maximum DC Reverse Current Ta=25 к
at Rated DC Blocking Voltage Ta=125 к
I2t Rating for fusing (t<8.3ms)
VF
IR
I2t
1.0
5.0
500
V
µA
A2S
pF
166
Typical Junction Capacitance
per element (Note1)
CJ
130
Typical Thermal Resistance (Note 2)
Operating Temperature Range
Storage Temperature Range
RșJC
TJ
TSTG
2.2
- 55 ~ + 150
- 55 ~ + 150
к / W
к
к
NOTES:
1. Measured at 1.0 MHz and applied reverse voltage of 4.0V D.C.
2. Device mounted on 50mm x 50mm x 1.6mm Cu Plate Heatsink.
http://www.SeCoSGmbH.com/
Any changing of specification will not be informed individual
Page 1 of 2