DATA SHEET
GBU10A~GBU10K
GLASS PASSIVATED SINGLE-PHASE BRIDGE RECTIFIER
VOLTAGE - 50 to 800 Volts CURRENT - 10.0 Amperes
Unit: inch ( mm )
GBU
FEATURES
(
.880 22.3
)
)
(
.860 21.8
• Plastic material has Underwriters Laboratory
Flammability Classification 94V-O
(
.160 4.1
)
(
.140 3.5
)
(
.140 3.56
)
)
(
.130 3.30
• Ideal for printed circuit board
• Reliable low cost construction utilizing molded plastic technique
• Surge overload rating: 200 Amperes peak
• High temperature soldering guaranteed:
(
.040 1.02
)
)
260°C/10 seconds/.375"(9.5mm) lead length at 5 lbs. (2.3kg) tension
(
.030 0.76
MECHANICALDATA
Case: Reliable low cost construction utilizing
molded plastic technique
(
.100 2.54
)
(
.022 0.56
)
)
.085(2.16)
(
.018 0.46
(
.080 2.03
)
)
Terminals: Leads solderable per MIL-STD-202,
Method 208
(
.065 1.65
(
.190 4.83
)
(
.050 1.27
)
Mounting position: Any
(
.210 5.33
)
(
.040 1.02
)
Mounting torque: 5 in. lb. Max.
Weight: 0.15 ounce, 4.0 grams
MAXIMUMRATINGSANDELECTRICALCHARACTERISTICS
Rating at 25°Cambient temperature unless otherwise specified. Resistive or inductive load, 60Hz.
For Capacitive load derate current by 20%.
UNIT
V
GBU10D
200
GBU10J
600
GBU10A
50
GBU10B
100
GBU10G
GBU10K
800
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Input Voltage
400
280
400
140
420
35
70
560
V
V
200
600
Maximum DC Blocking Voltage
50
100
800
Maximum Average Forward T =100°C
C
10.0
A
Rectified Output Current at
I2t Rating for fusing ( t<8.35ms)
A2sec
127
200
1.0
Peak Forward Surge Current single sine-wave superimposed on
rated load(JEDEC method)
Apk
Vpk
Maximum Instantaneous Forward Voltage Drop per element at 5.0A
5.0
µA
µA
Maximum Reverse Leakage at rated T =25°
A
500
CDc Blocking Voltage per element T =100°C
C
°C / W
°C / W
°C
8.6
3.1
Typical Thermal Resistance per leg(Note 2) RθJA
Typical Thermal Resistance per leg(Note 3) RθJC
-55+150
Operating and Storage Temperature Range, T ,TSTG
J
NOTES:
1. Recommended mounting position is to bolt down on heatsink with silicone thermal compound for maximum heat transfer with #6 screw.
2. Units Mounted in free air, no heatsink, P.C.B at 0.375"(9.5mm) lead length with 0.5 x 0.5"(12 x 12mm)copper pads.
3. Units Mounted on a 2.6 x 1.4" x 0.06" thick ( 6.5 x 3.5 x 0.15cm) AL plate.
DATE : AUG.29.2002
PAGE . 1