PLCDA03
thru
PLCDA24
. . . engineered solutions for the transient environment™
BIDIRECTIONAL LOW CAPACITANCE TVS ARRAYS
APPLICATIONS
✔✔Ethernet - 10/100 Base T
✔✔FireWire, SCSI & USB
✔✔Audio/Video Inputs
✔✔xDSL Interfaces
✔✔Cellular PhoneTerminals
IEC COMPATIBILITY (EN61000-4)
SO-8
✔✔61000-4-2 (ESD): Air - 15kv, Contact - 8kv
✔✔61000-4-4 (EFT): 40A - 5/50ns
✔✔61000-4-5 (Surge): 24A, 8/20µs - Level 2(Line-Gnd) & Level 3(Line-Line)
FEATURES
✔✔500 Watts Peak Pulse Power Dissipation(tp = 8/20µs)
✔✔Bidirectional Configuration
✔✔Available in 6 Voltage Types: 3.3V to 24V
✔✔Protects Up to Two (2) Lines
✔✔ESD Protection > 40 kilovolts
✔✔LOW CAPACITANCE -5pF
MECHANICAL CHARACTERISTICS
✔✔Molded JEDEC SO-8
✔✔Weight 15 milligrams (Approximate)
✔✔Flammability Rating UL 94V-0
✔✔12mmTape and Reel Per EIA Standard 481-1-A
✔✔Device Marking Code & Logo
✔✔Pin 1 Indicated By Dot on Package
CIRCUIT DIAGRAM
1
2
3
4
8
7
6
5
Note 1: For bidirectional applications,
connect external pins 1 &2, 3 & 4, 5 & 6
and 7 & 8 as shown in the circuit
diagram.
Note 2: Do not surge from pins 8 to 1, 2
to 7, 6 to 3, and 4 to 5. PIV typically
greater than 100V for each rectifier die.
05076.R5 1/02
1
www.protekdevices.com