40W Single Output
Medical & Industrial Grade
GB40 Family
FEATURES AND BENEFITS
Approved to CSA/EN/IEC/UL60601-1, 3rd Edition
E-cap Life of >8 Years
40W Open Frame and PCB-mount Power Supply
2.0” x 4.0” x 1.0” Package
Medical
Universal Input 90-264VAC
>1,000,000 Hours MTBF
<0.1W No Load Input Power
3 Year Warranty
Industrial
Approved to CSA/EN/IEC/UL62368-1
Meets Class B Radiated & Conducted EMI, with
Margin
Meets Heavy Industrial and IEC60601-1-2 4th
Edition Levels of EMC
Note: *Consult Factory for compliance information.
MODEL SELECTION
Rated
Current
Output
Power
Ripple &
Noise1
Line
Regulation
Load
Regulation
Input
Class/Termination
Output
Termination
Model Number2 Volts
Class I (Grounded) input,
ꢑ-pin AMP/Molex type
connectorꢆꢝ2ꢆꢞꢋꢟꢐꢆꢁꢄꢚꢈꢠꢄꢅꢡ
Change “K” to “C” for
class II input
75mV pk-pk
GB40S05K01
GB40S09K01
GB40S12K01
GB40S18K01
GB40S24K01
GB40S48K01
5.0V
9.0V
5.0A
4.0A
25W
36W
40W
40W
40W
40W
±1%
±1%
±1%
±1%
±1%
±1%
±5%
±5%
±5%
±5%
±5%
±5%
4-pin AMP/Molex type
connector for “K” and “C”
versions
90mV pk-pk
120mV pk-pk
120mV pk-pk
240mV pk-pk
480mV pk-pk
12.0V
18.0V
24.0V
48.0V
3.4A
Change “K” to “P” for PCB
mount pins, class I input
2.22A
1.7A
PCB mount pins for
“P” and “V” versions
Change “K” to “ꢔꢢꢆꢣꢈꢁꢆPCB
mount pins”, class II input
0.83A
Note: 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
2. Other output voltages available, consult factory.
3. All specifications are typical at 230VAC, full load, at 25°C ambient unless noted.
INPUT
OUTPUT
Input Voltage and
Frequency
<700ms
Turn On Time
Hold-Up Time
100-240VAC, ±10%, 47-63Hz, 1Ø
20ms/100VAC at full load
Input Current
115VAC: 1.2A, 230VAC: 0.6A
25W-40W continuous – See models chart for specific
voltage model ratings
Output Power
Output Voltage
264VAC, cold start: will not exceed 40A peak
3.15A, 250VAC fuse in both line and neutral
Inrush Current
Input Fuses
See models chart
Earth Leakage Current
(Input to Ground)
ꢍꢑ00ꢀꢏꢒ2ꢓ4ꢔꢏꢕꢉꢆꢓ0ꢖꢗꢉꢆꢘꢕ
ꢍꢙꢚꢏꢒ2ꢓ4ꢔꢏꢕꢉꢆꢓ0ꢖꢗꢉꢆꢛꢜꢕ
500ꢀs resp. time for return to w/in 0.5% of final
value for any 50% load step from 5% to 100% of
ꢁꢂꢃꢄꢅꢆꢇꢈꢂꢅꢉꢆꢊꢋꢌꢊꢃꢍ0ꢎ2ꢏꢌꢀꢐ
Transient Response
Regulation
Earth Leakage Current
(Output to Ground)
ꢍꢙ00ꢀꢏꢒ2ꢓ4ꢔꢏꢕꢉꢆꢓ0ꢖꢗꢉꢆꢘꢕ
ꢍꢑ00ꢀꢏꢒ2ꢓ4ꢔꢏꢕꢉꢆꢓ0ꢖꢗꢉꢆꢛꢜꢕ
Max voltage deviation is +/-3.5%
See models chart
Efficiency
>88%, typical
Note: All specifications are typical at 230VAC input, full load, at 25°C ambient unless noted.
0.9, min., 230VAC, 80-100% load vector, 25°C
ambient
Power Factor
Note: All specifications are typical at 230VAC input, full load, at 25°C ambient unless noted.
GB40Datasheet v0420
Copyright © 2020 SL Power Electronics Corp. All rights reserved.
Page 1