PCB Relay
G6C
SPST-NO Type Breaks 10-A Loads;
SPST-NO + SPST-NC Type
Breaks 8-A Load
■ Compact: 20 × 15 × 10 mm (L × W × H).
■ Low power consumption: 200 mW.
■ Flux protection or fully sealed construction avail-
able.
■ Unique moving loop armature reduces relay size,
magnetic interference, and contact bounce.
■ Single- and double-winding latching types also
available
RoHS Compliant
VDE
X
RC
+E
Ordering Information
Classification
Contact form
Straight PCB
Self-clinching PCB
Flux protection
Fully sealed
G6C-1114P-US
G6C-2114P-US
Flux protection
G6C-1117C-US
G6C-2117C-US
Fully sealed
G6C-1114C-US
G6C-2114C-US
Single-side stable
SPST-NO
G6C-1117P-US
G6C-2117P-US
SPST-NO + SPST-
NC
Single-winding
latching
SPST-NO
G6CU-1117P-US
G6CU-2117P-US
G6CU-1114P-US
G6CU-2114P-US
G6CU-1117C-US
G6CU-2117C-US
G6CU-1114C-US
G6CU-2114C-US
SPST-NO + SPST-
NC
Double-winding
latching
SPST-NO
G6CK-1117P-US
G6CK-2117P-US
G6CK-1114P-US
G6CK-2114P-US
G6CK-1117C-US
G6CK-2117C-US
G6CK-1114C-US
G6CK-2114C-US
SPST-NO + SPST-
NC
Note: When ordering, add the rated coil voltage to the model number.
Example: G6C-1117P-US 12 VDC
Rated coil voltage
Model Number Legend
G6C
-
-
-
VDC
1
2
3
4 5
6
7 8
1. Relay Function
None: Single-side stable
3. Contact Type
1: Standard
4. Enclosure Ratings
5. Terminals
P:
C:
Straight PCB
Self-clinching PCB
U:
K:
Single-winding latching
Double-winding latching
6. Approved Standards
4: Fully sealed
7: Flux protection
US: UL/CSA certified
2. Contact Form
11:
21:
SPST-NO
SPST-NO + SPST-NC
7. Mounting
None: Mounted directly to PCB
P6C: Mounted to Socket
8. Rated Coil Voltage
3, 5, 6, 12, or 24 VDC
196