G5V-2
General-purpose, Low-cost,
Low Signal Relay
Two-pole Relays for Signal Circults
•
•
•
General-purpose DIL terminal layout.
Wide switching power of 10 μA to 2 A.
Fully-sealed type Relays standardized with bifurcated crossbar contacts. Highly
reliable in addition to its high environment resistance.
•
•
•
Conforms to FCC Part 68 (impulse withstand voltage of 1,500 V for 10 x 160 µs
between coil and contacts and between contacts of the same polarity).
High dielectric strength at 1,000 VAC between coil and contacts, and 750 VAC
between contacts of the same polarity.
UL and CSA standard approved.
RoHS Compliant
■Model Number Legend
■Application Examples
1. Number of Poles/ Contact form 2. Classification
• Telecommunication equipment
• Security equipment
G5V-@-@
—
—
2: 2-pole/DPDT (2c)
None: Standard
H1: High-sensitivity
1
2
■Ordering Information
■Ratings
G
5
Minimum
packing
unit
●Coil
Enclosure Contact Terminal
Rated coil
voltage
Model
V
rating
form
shape
Must Must
Max.
Classification
operate release
voltage voltage
Rated
current resistance
(mA)
Coil
Power
consumption
(mW)
2
3 VDC
5 VDC
6 VDC
voltage
(V)
Rated
voltage
Classification
(V)
(V)
(Ω)
% of rated voltage
Standard
G5V-2
9 VDC
3 VDC 166.7
5 VDC 100
6 VDC 83.3
18
50
72
162
288
12 VDC
24 VDC
48 VDC
5 VDC
12 VDC
24 VDC
48 VDC
PCB
terminals
Fully
sealed
DPDT
(2c)
25
pcs/tube
Approx. 500
75%
5%
120%
Standard 9 VDC 55.6
12 VDC 41.7
max.
min. (at 23°C)
High-
sensitivity
G5V-2-H1
24 VDC 20.8 1,152
48 VDC 12
5 VDC 30
4,000
166.7
960
Approx. 580
Approx. 150
Approx. 200
Approx. 300
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-2 3 VDC
180%
(at 23°C)
12 VDC 12.5
Rated coil voltage
High-
sensitivity
75%
max.
5%
min.
24 VDC
8.33 2,880
■Characteristics
150%
(at 23°C)
48 VDC
6.25 7,680
Item
Classification
Standard
High-sensitivity
100 m max.
7 ms max.
3 ms max.
min. (at 500 VDC)
Note 1. The rated current and coil resistance are measured at a coil
temperature of 23°C with a tolerance of ±10%.
Contact resistance *1
Operate time
Release time
50 m
Ω
max.
Ω
2.Operating characteristics are measured at a coil temperature of 23°C.
3.The maximum voltage is the highest voltage that can be imposed on the
relay coil.
Insulation resistance *2
1,000 M
Ω
Between coil and
contacts
Between contacts
of the same polarity
Between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min
●Contacts
Dielectric
strength
750 VAC, 50/60 Hz 500 VAC, 50/60 Hz for
Classification
Standard
High-sensitivity
Resistive load
for 1 min 1 min
Load
1,000 VAC, 50/60 Hz for 1 min
Contact type
Contact material
Bifurcated crossbar
Ag + Au-alloy
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Destruction
Malfunction
Vibration
resistance
0.5 A at 125 VAC;
2 A at 30 VDC
0.5 A at 125 VAC;
1 A at 24 VDC
Rated load
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Rated carry current
Max. switching voltage
Max. switching current
2 A
125 VAC, 125 VDC
Destruction
Malfunction
1,000 m/s2
Shock
resistance
200 m/s2
100 m/s2
2 A
1 A
15,000,000 operations min.
(at 36,000 operations/hr)
Mechanical
AC: 100,000 operations
Durability
100,000 operations
min. (at 1,800
operations/hr)
min., DC: 300,000
operations min.
Electrical
(at 1,800 operations/hr)
Failure rate (P level) (reference
value) *3
10 μA at 10 m VDC
-25°C to 65°C
(with no icing or
condensation)
-25°C to 70°C
(with no icing or
condensation)
Ambient operating temperature
Ambient operating humidity
Weight
5% to 85%
Approx. 5 g
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage
drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter
applied to the same parts as those used for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min
and the criterion of contact resistance is 50 Ω. This value may vary
depending on the switching frequency and operating environment.
Always double-check relay suitability under actual operating conditions.
1