描述
SSR with Failure Detection Function

G3PC-220B-VD 数据手册

 浏览型号G3PC-220B-VD的Datasheet PDF文件第2页浏览型号G3PC-220B-VD的Datasheet PDF文件第3页浏览型号G3PC-220B-VD的Datasheet PDF文件第4页浏览型号G3PC-220B-VD的Datasheet PDF文件第5页浏览型号G3PC-220B-VD的Datasheet PDF文件第6页 
GSSR3wiPth FCailure Detection Function  
Detects failures in SSRs used for heater  
temperature control and simultaneously  
outputs alarm signals. This product  
supports the safe design of heater control  
systems, and contributes to maintenance  
improvements by the user.  
Main detection items:  
SSR short-circuits and SSR open-circuits  
Alarm output possible to NPN/PNP-input devices.  
The failure-detection function is built-in and power is supplied  
from the main circuit power supply making wiring simple.  
Slim design (width: 22.5 mm) incorporating radiator.  
In addition to screw mounting, DIN track mounting is also pos-  
sible.  
Conforms to international standards (IEC, UL, and CSA).  
Ordering Information  
I List of Models  
Insulation method  
Zero-cross function  
Indicators  
Applicable output load  
Model number  
G3PC-220B-VD  
Phototriac coupler  
Yes  
Yes  
(See page 75)  
20 A, 100 to 240 VAC  
(resistive load: AC, Class1)  
I Accessories (Order Separately)  
Name  
Dimensions  
50 cm (l) × 7.3 mm (t)  
1 m (l) × 7.3 mm (t)  
1 m (l) × 16 mm (t)  
Model number  
Mounting Track  
PFP-50N  
PFP-100N  
PFP-100N2  
Specifications  
I Ratings (At an Ambient Temperature of 25°C)  
Detection Power Supply  
Main Circuit  
Rated power supply voltage  
Operating voltage range  
Current consumption  
100 to 240 VAC (50/60 Hz)  
Rated load voltage  
100 to 240 VAC (50/60 Hz)  
75 to 264 VDC (50/60 Hz)  
20 A (Ta = 40)  
75 to 264 VAC (50/60 Hz)  
Operating voltage range  
Rated carry current  
15 mA AC max. (at 200 VAC)  
Minimum load current  
Inrush current resistance (peak value)  
Permissible (I2t)  
0.1 A  
Operating Circuit  
220 A (60 Hz, 1 cycle)  
260 A2S  
Input method  
Voltage input  
Applicable load  
(with Class-1 AC resistive load)  
4 kW (at 200 VAC)  
Rated input voltage  
12 to 24 VDC  
Operating input voltage  
range  
9.6 to 30 VDC  
Alarm Output  
Output OFF collector voltage  
Maximum carry current  
Output form  
Must-operate voltage  
Reset voltage  
9.6 VDC max.  
1 VDC min.  
30 VDC max.  
0.1 A  
Independent NPN open collector  
Input current  
7 mA DC max. (at rated input voltage)  
SSR with Failure Detection Function G3PC  
J-71  

与G3PC-220B-VD相关器件

型号 品牌 获取价格 描述 数据表
G3PE OMRON

获取价格

Single-phase Solid State Relays for Heaters
G3PE-215B OMRON

获取价格

Single-phase Solid State Relays for Heaters
G3PE-215BDC12-24 OMRON

获取价格

Trigger Output SSR, 1-Channel, 2500V Isolation, ROHS COMPLIANT PACKAGE-4
G3PE-215BL OMRON

获取价格

Single-phase Solid State Relays for Heaters
G3PE-215BLDC12-24 OMRON

获取价格

Trigger Output SSR, 1-Channel, 2500V Isolation, ROHS COMPLIANT PACKAGE-4
G3PE-225B OMRON

获取价格

Single-phase Solid State Relays for Heaters
G3PE-225BDC12-24 OMRON

获取价格

Trigger Output SSR, 1-Channel, 2500V Isolation, ROHS COMPLIANT PACKAGE-4
G3PE-225BL OMRON

获取价格

Single-phase Solid State Relays for Heaters
G3PE-225BLDC12-24 OMRON

获取价格

Trigger Output SSR, 1-Channel, 2500V Isolation, ROHS COMPLIANT PACKAGE-4
G3PE-235B OMRON

获取价格

Single-phase Solid State Relays for Heaters