APPLICABLE STANDARD
OPERATING
STORAGE
-10 C TO 60 C (2)
40 % TO 70 %
-55 C TO 85 C (1)
TEMPERATURE RANGE
TEMPERATURE RANGE
STORAGE HUMIDITY
RANGE
(2)
RATING
100 V AC
VOLTAGE
CURRENT
OPERATING HUMIDITY
RANGE
(3)
0.5 A (SIGNAL CONTACT)
3 A (MF CONTACT)
RELATIVE HUMIDITY 85% max
(NOT DEWED)
SPECIFICATIONS
ITEM
CONSTRUCTION
TEST METHOD
REQUIREMENTS
QT AT
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
ACCORDING TO DRAWING.
×
×
×
×
MARKING CONFIRMED VISUALLY.
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
100 mA(DC OR 1000Hz)
SIGNAL CONTACT
MF CONTACT
:
90 mΩMAX.
30 mΩMAX.
×
-
:
INSULATION RESISTANCE
VOLTAGE PROOF
250 V DC.
1000 MΩMIN.
NO FLASHOVER OR BREAKDOWN.
×
×
-
-
300 V AC FOR 1 min.
MECHANICAL CHARACTERISTICS
INSERTION AND
WITHDRAWAL FORCES
MECHANICAL
MEASURED BY APPLICABLE CONNECTOR.
INSERTION FORCE:
WITHDRAWAL FORCE:
70
7
N MAX.
N MIN.
×
×
-
-
500 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE:
SIGNAL CONTACT : 100 mΩMAX.
MF CONTACT 40 mΩMAX.
OPERATION
:
② NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
VIBRATION
SHOCK
FREQUENCY 10 TO 55 TO 10Hz, APPROX 5min
SINGLE AMPLITUDE : 0.75 mm, 10 CYCLES
① NO ELECTRICAL DISCONTINUITY OF
×
×
-
-
1 s.
FOR
490 m/s2 , DURATION OF PULSE 11 ms
AT TIMES FOR DIRECTIONS.
3
DIRECTIONS.
② NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
3
3
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
(STEADY STATE)
EXPOSED AT
40±2 C, 90 ~ 95 %, 96 h. ① CONTACT RESISTANCE:
SIGNAL CONTACT : 100 mΩMAX.
MF CONTACT 40 mΩMAX.
② INSULATION RESISTANCE
:1000 M MIN.
×
×
-
-
:
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55
→
→
+85 C
30 min.
TIME
30
CYCLES.
UNDER
5
(RELOCATION TIME TO CHAMBER:WITHIN 2~3 MIN)
③ NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
SULFUR DIOXIDE
NO HEAVY CORROSION.
EXPOSED AT 25±2℃, 75±5%RH, 25 PPM FOR
96 h.
(TEST STANDARD: JIS C 60068)
1)REFLOW SOLDERING :
×
×
-
-
RESISTANCE TO
SOLDERING HEAT
NO DEFORMATION OF CASE OF
EXCESSIVE LOOSENESS OF THE
TERMINAL.
PEAK TMP : 260℃MAX
REFLOW TMP: 220℃MIN FOR 60sec
2) SOLDERING IRONS : 360℃ MAX. FOR 5 sec.
SOLDERED AT SOLDER TEMPERATURE
240±3℃ FOR IMMERSION DURATION, 3 sec.
A NEW UNIFORM COATING OF SOLDER
SHALL COVER A MINIMUM OF 95 % OF THE
SURFACE BEING IMMERSED.
SOLDERABILITY
×
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(1) INCLUDE TEMPERATURE RISE CAUSED BY CURRENT-CARRYING.
(2) “STORAGE” MEANS A LONG-TERM STORAGE STATE
REMARKS
APPROVED
CHECKED
HS.OKAWA
15.06.30
15.06.30
HT.YAMAGUCHI
FOR THE UNUSED PRODUCT BEFORE ASSEMBLY TO PCB.
(3) THE RATED CURRENT APPLIES TO PER CONTACT.
DESIGNED
DRAWN
TH.SANO
TH.SANO
15.06.30
15.06.30
APPLY 0.4A WHEN ALL THE CONTACTS ARE USED FOR CURRENT CARRYING.
Unless otherwise specified, refer to JIS-C-5402.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
ELC-349365-00-00
FX18-120PS-0.8H15
CL579-0053-6-00
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CODE NO.
FORM HD0011-2-1