P O W E R T R A N S F O R M E R
P C M O U N T : SPLIT PACK
FS56-650
Description:
The FS56-650 is a dual primary and dual secondary, split bobbin design which
operates with either a parallel input of 115V or a series input of 230V. The output
voltage will be either 56.0V with a center-tap under a 0.65A load with the
secondaries wired in series, or 28.0V under a 1.3A load with the secondaries
wired in parallel. The split bobbin design eliminates the need for costly
electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 36.0VA
2. Primary:
Series: 230V; Parallel: 115V
3. Secondary: Series: 56.0V CT@ 0.65A; Parallel: 28.0V @ 1.3A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
W
6. Hipot tested 100% at 2500 VRMS
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
E
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
L
This model is also available in Class 3, UL 5085-3 (1585) version as FS56-650-C2
H
Dimensions:
Units in inches.
H
1.562
W
2.187
L
A
0.400
B
0.400
C
1.850
D
0.041
E
0.020
F
1
2
3
4
2.625
0.234
Weight: 1.10 lbs
D
F
Schematic:
PARALLEL
SERIES
1
5
1
1
A
A
5
8
115/230V
50/60Hz
2
3
6
7
115/230V
50/60Hz
2
3
115/230V
50/60Hz
2
3
B
4
8
4
4
C
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
1
4
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2
and 5085-3, respectively.
0.06" DIAMETER
HOLE
Board Layout
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013