5秒后页面跳转
FS1601-9RTB2 PDF预览

FS1601-9RTB2

更新时间: 2024-12-02 08:18:19
品牌 Logo 应用领域
BEL 电源电路
页数 文件大小 规格书
33页 438K
描述
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE

FS1601-9RTB2 数据手册

 浏览型号FS1601-9RTB2的Datasheet PDF文件第2页浏览型号FS1601-9RTB2的Datasheet PDF文件第3页浏览型号FS1601-9RTB2的Datasheet PDF文件第4页浏览型号FS1601-9RTB2的Datasheet PDF文件第5页浏览型号FS1601-9RTB2的Datasheet PDF文件第6页浏览型号FS1601-9RTB2的Datasheet PDF文件第7页 
S Series Data Sheet  
100 Watt AC-DC and DC-DC Converters  
Features  
Input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47-440 Hz  
1or 2 isolated outputs up to 48 VDC  
Class I equipment  
RoHS lead solder exemption compliant  
Extremely-wide input voltage range  
Input over- and undervoltage lockout  
Efficient input filter and built-in surge and transient  
suppression circuitry  
Outputs: SELV, no-load, and short-circuit proof  
No derating over entire operating temperature range  
PCBs coated with protective lacquer  
Very high reliability  
111  
4.4"  
3 U  
60  
2.4"  
12 TE  
168  
6.6"  
Safety according to IEC/EN 60950  
Description  
The S Series AC-DC and DC-DC converters represents a broad  
and flexible range of power supplies for use in advanced  
electronic systems. Features include high efficiency, high  
reliability, low output voltage noise and excellent dynamic  
response to load/line changes. LS models can be powered by  
DC or AC with a wide-input frequency range (without PFC).  
The case design allows operation at nominal load up to 71 °C in a  
free-air ambient temperature. If forced cooling is provided, the  
ambient temperature may exceed 71 °C, but the case temperature  
must remain below 95 °C under all conditions.  
A temperature sensor generates an inhibit signal, which disables  
the outputs if the case temperature T exceeds the limit. The  
c
The converter inputs are protected against surges and  
transients. An input over- and undervoltage lockout circuitry  
disables the outputs if the input voltage is outside of the  
specified range. Certain types include an inrush current limiter  
preventing circuit breakers and fuses from tripping at switch-on.  
outputs are automatically re-enabled when the temperature drops  
below the limit.  
Various options are available to adapt the converters to individual  
applications.  
The converters may either be plugged into a 19" rack system  
according to IEC 60297-3, or be chassis mounted. They are ideally  
suited for Railway applications.  
All outputs are open- and short-circuit proof and are protected  
against overvoltages by means of built-in suppressor diodes.  
The outputs can be inhibited by a logic signal applied to pin 18  
(i). If the inhibit function is not used, pin 18 must be connected  
with pin 14 to enable the outputs.  
Important: For applications requiring compliance with IEC/EN  
61000-3-2 (harmonic distortion), please use our LS4000 and LS5000  
Series with incorporated power factor correction (PFC).  
LED indicators display the status of the converter and allow for  
visual monitoring of the system at any time.  
Full input-to-output, input-to-case, output-to-case and output-to-  
output isolation is provided. The converters are designed and  
built according to the international safety standards IEC/EN  
60950 and EN50155. They have been approved by the safety  
agencies TÜV and UL (for USA and Canada).  
Table of Contents  
Page  
Page  
Description ................................................................................1  
Model Selection ........................................................................2  
Part Number Description and Product Marking ........................3  
Functional Description ..............................................................4  
Electrical Input Data..................................................................5  
Electrical Output Data ..............................................................8  
Auxiliary Functions..................................................................12  
Electromagnetic Compatibility (EMC) ....................................15  
Immunity to Environmental Conditions ..................................17  
Mechanical Data ....................................................................18  
Safety and Installation Instructions ........................................19  
Description of Options ............................................................23  
Accessories ............................................................................32  
EC-Declaration of Conformity ................................................33  
APR 26, 2006 revised to SEP 25, 2006  
Page 1 of 33  
www.power-one.com  

与FS1601-9RTB2相关器件

型号 品牌 获取价格 描述 数据表
FS16-070 TRIAD

获取价格

FS16-070
FS16-070-C2 TRIAD

获取价格

Split Bobbin Power Transformer, 1.1VA, ROHS COMPLIANT
FS1610 ETC

获取价格

STANDARD SCR
FS1610BH ETC

获取价格

Standard Gate SCRs
FS1610BH00TU ETC

获取价格

STANDARD SCR
FS1610DH ETC

获取价格

Standard Gate SCRs
FS1610MH ETC

获取价格

Standard Gate SCRs
FS16-1250 TRIAD

获取价格

Split Bobbin Power Transformer, 20VA, ROHS COMPLIANT
FS16-1250-C2 TRIAD

获取价格

Split Bobbin Power Transformer, 20VA, ROHS COMPLIANT
FS1614BH ETC

获取价格

Standard Gate SCRs