Flashers and Tower Lighting Controls
Tower and Obstruction Lighting Controls
FA / FS SERIES
*
*(FS155 & FA155 models only)
Description
FA155
The FA/FS Series have proven their reliability through years of
use on communication towers, smoke stacks, cooling towers,
tall buildings, bridges and utility towers. The highest quality
components are encapsulated in a rugged plastic housing with
a molded-in heat transfer plate. The flash rate, ratio, and fail-
safe design meet FAA regulations. Zero voltage switching can
increase lamp life up to ten times. The FS155-30RF includes
superior RF filtering circuitry for use in high RF installations,
including AM hot towers.
FS165-30T
Wiring Diagram
L1
L2
N/L2
L1
(H)
Operation
FS Series - Flasher (OFF First)
FA Series - Auxiliary Modules
Upon application of input voltage, theT2 OFF time begins. At
the end of the OFF time, theT1 ON time begins and the load
energizes. At the end ofT1, T2 begins and the load de-energizes.
This cycle repeats until voltage is removed.
FS Series
FA155-2
N/L2
L1
L1
N/L2
(H)
Reset: Removing input voltage resets the output and the
sequence toT2.
Features & Benefits
FEATURES
BENEFITS
Zero voltage switching
Encapsulated
Delivers up to 10 times longer lamp life
Protects against shock, vibration, and humidity
FA155
FA165
FA155-2
FA165-2
Metalized
Facilitates heat transfer in high current applications
Ideal for AM hot towers and other high
mounting surface
Superior RF filtering
circuitry (RF models only) RF installations
V = Voltage
N = Neutral
B = Beacon
High inrush capability
up to 200A
Will withstand the repetitive inrush current of
incandescent beacons
DL = Dummy Load for Constant Line Loading
Rd = 3.3 KΩ @ 5W for 120VAC; 8.5 KΩ @ 5W for 230VAC
F = Flasher (FS155-30T, FS155-30RF, FS165-30T)
AX = Auxiliary Unit (FA155, FA155-2, FA165, FA156-2)
Ordering Information
MODEL
INPUT VOLTAGE WATTAGE INRUSH RATING DESCRIPTION
FA155
120VAC
120VAC
230VAC
230VAC
2500W
2500W
5000W
5000W
200A
200A
200A
200A
Auxiliary unit to provide constant line loading
Auxiliary unit for synchronized operating of additional beacons. Synchronized flashing of
additional beacons on a 3 wire system
FA155-2
FA165
Auxiliary unit to provide constant line loading
Specifications
Auxiliary unit for synchronized operating of additional beacons. Synchronized flashing of
FA165-2
additional beacons on a 2 wire system
For high RF interference locations including AM hot towers
Standard beacon flasher
FS155-30RF 120VAC
2500W
2500W
5000W
200A
200A
200A
FS155-30T
FS165-30T
120VAC
230VAC
Standard beacon flasher
If you don’t find the part you need, call us for a custom product 800-843-8848