FR601 THRU FR607
6.0 AMPS. Fast Recovery Rectifiers
Voltage Range
50 to 1000 Volts
Current
6.0 Amperes
R-6
Features
ꢀ
ꢀ
ꢀ
ꢀ
Low forward voltage drop
High current capability
High reliability
High surge current capability
Mechanical Data
ꢀ
ꢀ
ꢀ
Cases: Molded plastic
Epoxy: UL 94V-0 rate flame retardant
Lead: Axial leads, solderable per MIL-
STD-202, Method 208 guaranteed
Polarity: Color band denotes cathode end
High temperature soldering guaranteed:
260℃/10 seconds/.375”,(9.5mm) lead
lengths at 5 lbs.,(2.3kg) tension
Weight: 1.65 grams
ꢀ
ꢀ
ꢀ
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
FR601 FR602 FR603 FR604 FR605 FR606 FR607
Symbol
VRRM
VRMS
Type Number
Maximum Recurrent Peak Reverse Voltage
Units
50
35
50
100 200 400 600 800 1000
70 140 280 420 560 700
100 200 400 600 800 1000
V
V
V
Maximum RMS Voltage
Maximum DC Blocking Voltage
VDC
Maximum Average Forward Rectified
Current .375”(9.5mm) Lead Length
@TA = 55℃
I(AV)
6.0
A
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 6.0A
IFSM
200
1.2
A
V
VF
IR
Maximum DC Reverse Current @ TA=25℃
10
200
uA
uA
nS
at Rated DC Blocking Voltage @ TA=100℃
Maximum Reverse Recovery Time ( Note 1 )
Typical Junction Capacitance ( Note 2 )
Typical Thermal Resistance ( Note 3 )
Operating Temperature Range
Trr
Cj
RθJA
TJ
150
250
500
80
30
pF
OC/W
℃
-65 to +150
-65 to +150
℃
Storage Temperature Range
TSTG
Notes:1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1 MHz and Applied Reverse Voltage of 4..0 Volts D.C.
3. Mount on Cu-Pad Size 16mm x 16mm on P.C.B.
- 416 -