Single-Stage Filters FN 2030
DATASHEET
General Purpose AC/DC EMI Filter with High Attenuation Performance
Rated currents from 1 to 30 A
Approvals & Compliances
High performance filter attenuation
High differential-mode attenuation
Optional medical versions (B type)
Optional safety versions (A type)
Optional enhanced performance versions
Optional overvoltage protection (Z type)
Features and benefits
FN 2030 filters are designed for easy and fast chassis
mounting
FN 2030 B versions without capacitors to earth
comply to 1MOP for ME (medical equipment) acc.
IEC 60601-1
Performance indicators
FN 2030 A versions with low capacitance to earth
for safety critical applications with a requirement for
low leakage currents
FN 2030 filters offer an optimized filter range for
high performance AC and DC applications , in same
compact size (M, N1 types)
All filters provide an exceptional conducted
attenuation performance, based on chokes with
high permeable core material and excellent thermal
behavior
Technical specifications
The higher inductivity versus amperage offers
increased attenuation performance with same form
factor compared to FN 2010 and FN 2020 filter series
250 VAC, 50/60 Hz; 250 VDC
DC to 400 Hz
Rated voltage*
Operating frequency
Rated currents
All FN 2030 filters can be delivered with optional
surge pulse protection (Z type).
1 to 30 A @ 40°C max.
P –> PE 2000 VAC for 2 sec (equiv. cap <88 nF)
P –> PE 2550 VDC for 2 sec (equiv. cap >88 nF)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 1100 VDC for 2 sec
Various terminal options allow you to select the
desired connection style
High potential test voltage
Typical application
-25°C to +100°C (25/100/21)**
Temperature range (operation and storage)
Certified to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to
AC and DC applications)
Electrical and electronic equipment
Consumer goods
Terminal plastic for -06/-08 version: UL 94 V-0
Laces for -07 version: UL 94 VW-1
Flammability corresponding to
Household equipment
Grommet for -07 version: UL 94 V-0
Medical equipment
II acc. IEC 60664-1
Overvoltage category
Pollution degree
Electronic data processing equipment
Office automation and datacom equipment
2 acc. IEC 60664-1
2000m (above derating applies)**
Altitude
Various noisy applications requiring high filter
performance
2,200,000 hours (1 to 10 A types)
1,200,000 hours (12 to 30 A types)
MTBF @ 40°C/230 V (Mil-HB-217F)
Helps compliance to IEC61000-4-5 (Differential Mode
only)
Surge pulse protection (Z type)
Typical electrical schematic
* maximum RMS operating voltage at rated frequency or the maximum DC operating voltage
** for dedicated requests exceeding this specification (e.g. -40 °C or higher altitude) please contact your local