5秒后页面跳转
FLU1-40-2AD PDF预览

FLU1-40-2AD

更新时间: 2022-02-26 11:14:05
品牌 Logo 应用领域
SLPOWER 开关
页数 文件大小 规格书
4页 469K
描述
OPEN-FRAME SWITCHING POWER SUPPLIES

FLU1-40-2AD 数据手册

 浏览型号FLU1-40-2AD的Datasheet PDF文件第2页浏览型号FLU1-40-2AD的Datasheet PDF文件第3页浏览型号FLU1-40-2AD的Datasheet PDF文件第4页 
40W  
OPEN-FRAME SWITCHING POWER SUPPLIES  
Single, Dual and Triple Output Models  
Universal AC-Input and DC-Input Models  
CE Mark: UL/CSA/EN60950 Approvals  
BABT Approvals  
Austel CCL Certification  
Models with UL544/CSA C22.2-601/EN60-601  
Medical Safety Approvals  
EN55022/FCC Class B Input Line Filter  
0% Minimum Load Requirement  
Over-Current/Short-Circuit Protection  
2-Year Warranty  
Minimum 200,000-Hour MTBF  
CHARACTERISTICS  
Output Current Output  
Input Voltage.............................FLU and MDU models, universal  
input range 85-265 VAC single  
Output Voltage Min. Nom. Max. Voltage Line Load Cross-  
Model  
Output (V)  
(A)  
(A)  
(A)  
Tol. Reg. Reg. Reg.  
phase or 100-370 VDC. DC-input  
models, 36-75 VDC (48V, nominal).  
AC-DC Singles  
85-265 VAC Input  
Input Line Frequency................47-440 Hz (ac input models).  
Input Line Protection.................MOV transient protected (FLU and  
MDU series). Input line fuse provid-  
ed on-board. (See Note 1.)  
EMI Filter...................................Standard. Performance surpasses  
conducted EMI requirements of  
FLU1-40-1AD  
FLU1-40-2AD  
FLU1-40-3AD  
FLU1-40-4AD  
FLU1-40-5AD  
FLU1-40-6AD  
V1  
V1  
V1  
V1  
V1  
V1  
5
0.0 8.00 8.00 1.0% 0.1% 0.2%  
0.0 4.40 4.40 1.0% 0.1% 0.2%  
0.0 3.30 3.30 1.0% 0.1% 0.2%  
0.0 2.70 2.70 1.0% 0.1% 0.2%  
0.0 1.70 1.70 1.0% 0.1% 0.2%  
0.0 1.40 1.40 1.0% 0.1% 0.2%  
9
12  
15  
24  
28  
EN55022/FCC Class B by 10 dB, typ.  
DC Output.................................See table. (Note 2.)  
Continuous Output Power.........40W, maximum.  
Leakage Current .......................MDU Series, non-patient contact rat-  
ing: 500 µA, maximum.  
Output Voltage Adjust ...............Primary output adjustable ±5%.  
Auxiliary outputs fixed.  
Efficiency...................................62-75%, typical (nominal input line  
voltage, nominal load conditions).  
Hold-Up Time............................FLU and MDU models: 16 ms (115  
VAC input), 32 ms (230 VAC input),  
AC-DC Singles  
MDU1-40-1AD V1  
MDU1-40-2AD V1  
MDU1-40-3AD V1  
MDU1-40-4AD V1  
MDU1-40-5AD V1  
MDU1-40-6AD V1  
To UL544/EN60-601/CSA 22.2-601.1  
5
0.0 8.00 8.00 1.0% 0.1% 0.2%  
0.0 4.40 4.40 1.0% 0.1% 0.2%  
0.0 3.30 3.30 1.0% 0.1% 0.2%  
0.0 2.70 2.70 1.0% 0.1% 0.2%  
0.0 1.70 1.70 1.0% 0.1% 0.2%  
0.0 1.40 1.40 1.0% 0.1% 0.2%  
9
12  
15  
24  
28  
minimum, at full load  
AC-DC Duals  
85-265 VAC Input  
Overload Protection ..................Power-limit circuit.  
Short-Circuit Protection.............Continuous.  
Over-Voltage Protection............Primary output only.  
Soft Start...................................Standard on all models.  
Design Topology .......................Flyback converter with current-mode  
control.  
Frequency of Operation............40 kHz (fixed).  
Hi-Pot Isolation..........................FLU Series: 5300 VDC, input-to-out-  
put for one minute. (Note 3.)  
FLU2-40-1AD  
FLU2-40-2AD  
FLU2-40-3AD  
FLU2-40-4AD  
FLU2-40-5AD  
FLU2-40-6AD  
FLU2-40-7AD  
V1  
+5  
0.0 3.00 5.00 1.0% 0.2% 1.0%  
V2 +12  
V1 +5  
V2 +15  
V1 +5  
V2 +24  
V1 +5  
0.0 2.00 3.00 5.0% 0.5% 3.0% 4.0%  
0.0 3.00 5.00 1.0% 0.2% 1.0%  
0.0 1.70 2.00 5.0% 0.5% 3.0% 4.0%  
0.0 3.00 5.00 1.0% 0.2% 1.0%  
0.0 1.00 1.50 5.0% 0.5% 3.0% 4.0%  
0.0 3.00 5.00 1.0% 0.2% 1.0%  
0.0 1.00 1.00 5.0% 0.5% 3.0% 4.0%  
0.0 6.00 6.00 1.0% 0.2% 1.0%  
0.0 2.00 2.00 3.0% 0.5% 1.0% 1.0%  
V2 +28  
MDU Series: 5700 VDC, input-to-out-  
put for one minute. (Note 3.)  
V1 5(ISO)  
V2 5(ISO)  
Noise, Ripple and Spike ...........1% peak-to-peak, maximum. (See  
Note 5.)  
Temperature Range ..................-20°C to +70°C.  
Output Power De-Rating...........De-rate output power and current  
linearly 2%/°C from +50°C to +70°C.  
V1 12(ISO) 0.0 2.00 3.00 1.0% 0.2% 1.0%  
V2 12(ISO) 0.0 1.00 2.00 3.0% 0.5% 1.0% 1.0%  
V1 15(ISO) 0.0 1.50 2.50 1.0% 0.2% 1.0%  
V2 15(ISO) 0.0 1.20 2.00 3.0% 0.5% 1.0% 1.0%  
Temperature Coefficient............±0.05%/°C over the entire operating  
temperature range.  
AC-DC Duals  
To UL544/EN60-601/CSA 22.2-601.1  
Relative Humidity......................0 to 95%, non-condensing.  
Altitude......................................0 to 10,000 feet.  
Cooling......................................Convection cooling is adequate.  
Moving air is recommended for oper-  
MDU2-40-1AD V1  
+5  
0.0 3.00 5.00 1.0% 0.2% 1.0%  
0.0 2.00 3.00 5.0% 0.5% 3.0% 4.0%  
0.0 3.00 5.00 1.0% 0.2% 1.0%  
0.0 1.70 2.00 5.0% 0.2% 3.0% 4.0%  
0.0 3.00 5.00 1.0% 0.2% 1.0%  
0.0 1.00 1.50 5.0% 0.2% 3.0% 4.0%  
0.0 3.00 5.00 1.0% 0.2% 1.0%  
0.0 1.00 1.00 5.0% 0.5% 3.0% 4.0  
V2 +12  
MDU2-40-2AD V1  
+5  
V2 +15  
ation in a confined area.  
MDU2-40-3AD V1  
+5  
Storage Temperature ................-40°C to +85°C.  
Storage Humidity ......................0 to 95%, non-condensing.  
Mean Time Between Failures ...>200,000 hours. (Note 6.)  
V2 +24  
MDU2-40-4AD V1  
+5  
V2 +28  
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com  
08  

与FLU1-40-2AD相关器件

型号 品牌 描述 获取价格 数据表
FLU1-40-3AD SLPOWER OPEN-FRAME SWITCHING POWER SUPPLIES

获取价格

FLU1-40-4AD SLPOWER OPEN-FRAME SWITCHING POWER SUPPLIES

获取价格

FLU1-40-5AD SLPOWER OPEN-FRAME SWITCHING POWER SUPPLIES

获取价格

FLU1-40-6AD SLPOWER OPEN-FRAME SWITCHING POWER SUPPLIES

获取价格

FLU1-50-1AD SLPOWER OPEN-FRAME SWITCHING POWER SUPPLIES

获取价格

FLU1-50-2AD SLPOWER OPEN-FRAME SWITCHING POWER SUPPLIES

获取价格