APPLICABLE STANDARD
Operating Temperature
Range
Storage Temperature
Range
-40C to +85C
AC 250 V
- C to - C
- % to - %
-
Operating Humidity
Range
Rating
Voltage
Current
Applicable Cable
1 A
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
ELECTRIC CHARACTERISTICS
Contact Resistance
Contact resistance: 70 mΩ max.
Shell resistance:10 mΩ max
1000 M min.
10 mA max (DC or 1000 Hz).
X
X
Insulation Resistance
Voltage Proof
250 V DC.
X
X
X
X
No flashover or breakdown.
500 V AC for 1 min.
MECHANICAL CHARACTERISTICS
Insertion force
78.4 N max.
Insertion and
Measured by applicable connector.
-
X
X
Withdrawal Forces
Mechanical Operation
Extraction farce 19.6 N min.
500 times insertions and extractions.
1) Contact resistance: 70 mΩ max.
Shell resistance:10 mΩ max.
-
2) No damage, crack and looseness of parts.
Vibration
Shock
Frequency 10 to 500 Hz single amplitude 0.75 mm,
98 m/s2 at 3h for 6 directions.
490 m/s2 duration of pulse 11 ms
At 3 times for 6 directions.
1) No electrical discontinuity of 1s.
2) Contact resistance: 70 mΩ max.
Shell resistance:10 mΩ max.
X
X
-
-
3) No damage, crack and looseness of parts.
ENVIRONMENTAL CHARACTERISTICS
Rapid Change of Temperature Temperature –40 → 5 to 35 → 105 → 5 to 35 C
1) Contact resistance: 70 mΩ max.
Shell resistance: 10 mΩ max.
Time
30 →
5
→ 30 → 5 min.
Under 10 cycles.
2) Insulation resistance: 1000 M min.
3) No flashover or breakdown.
4) No damage, crack and looseness of parts.
Mated connector with contacts connected
in series. Exposed with current carrying at
temperature 85℃, humidity 85% for 1000h.
DC 0.5A , 30V
-
Damp Heat/
Current Carrying
X
Leave at room temperature for 2h after testing.
Mated connector with contacts connected
In series. Exposed with current carrying at
temperature 105℃, for 1000h.
Dry Heat/
Current Carrying
DC 0.5A , 30V
Leave at room temperature for 2h after testing.
Leave at -40 ℃, for 500h
Cold Resistance
Corrosion Salt Mist
1) Contact resistance: 70 mΩ max.
Shell resistance: 10 mΩ max.
-
-
X
X
Leave at 5 to 30℃ for 1 to 2h after testing.
2) No damage, crack and looseness of parts.
Exposed in 5% salt water spray for 48 h.
1) Contact resistance: 70 mΩ max.
Shell resistance: 10 mΩ max.
2) Insulation resistance: 25 M min.
3) No heavy corrosion.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
KI.NAGANUMA
KI.NAGANUMA
JY.IGA
18.06.27
18.06.27
18.06.27
18.06.27
Unless otherwise specified, refer to IEC 60512.
JY.IGA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-125831-00-00
FI40B-20S-CV2
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/2
CL230-0540-6-00
FORM HD0011-2-1