APPLICABLE STANDARD
Operating
Storage Temperature
Range
-40 ℃ TO +85 ℃(Note 1)
- ℃ TO - ℃
φ6.2±0.3
Temperature Range
Rating
Voltage
Current
250 V AC
1 A
Applicable Cable
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT
AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
x
x
x
x
Marking
ELECTRICAL CHARACTEREISTICS
Contact Resistance
Between contact : 70 mΩ max.
Measured at 20 mV DC max, 10 mA (DC or 1000 Hz).
x
x
Between shell
: 10 mΩ max.
Insulation Resistance
Voltage Proof
250 V DC
500 V AC. for 1 min.
1000 MΩ min.
x
x
x
x
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Mating and Unmating Forces Measured with an applicable connector.
Mating force : 78.4 N max.
Unmating force : 19.6 N max.
x
x
-
-
Mechanical Operation
Mated and unmated 500 times.
① Contact resistance : 70 mΩ max.
Shell resistance : 10 mΩ max.
② No damage, crack and looseness of parts.
Vibration
Shock
Frequency : 10 to 500 Hz, singe amplitude 0.75 mm,
98 m/s2 at 3h for 6 directions.
490 m/s2 duration of pulse 11 ms for 3 times
① No electrical discontinuity of 1 μs.
② Contact resistance : 70 mΩ max.
x
x
-
-
Shell resistance
: 10 mΩ max.
in 3 both axial directions.
③ No damage, crack and looseness of parts.
ENVIRONMENTAL CHARACTERISTICS
Temperature –40 → 5 to 35 → 105 → 5 to 35 ℃
Rapid Change of Temperature
① Contact resistance : 70 mΩ max.
x
-
Time
30 →
5
→ 30 → 5 min
Shell resistance
: 10 mΩ max.
Under 10 cycles.
② Insulation resistance : 1000 MΩ min.
③ No flashover or breakdown.
④ No damage, crack and looseness of parts.
Damp Heat/
Mated connector with contacts connected in series.
Exposed with current carrying at temperature 85℃,
humidity 85% for 1000h.
① Contact resistance : 70 mΩ max.
x
x
-
-
Current Carrying
Shell resistance
: 10 mΩ max.
② Insulation resistance : 1000 MΩ min.
③ No flashover or breakdown.
DC 0.5A , 30V
Leave at room temperature for 2h after testing.
Mated connector with contacts connected in series.
Exposed with current carrying at temperature 105℃,
for 1000h.
④ No damage, crack and looseness of parts.
Dry Heat/
Current Carrying
DC 0.5A , 30V
Leave at room temperature for 2h after testing.
Leave at -40 ℃, for 500h
Cold Resistance
① Contact resistance : 70 mΩ max.
x
x
-
-
Leave at 5 to 35℃ for 1 to 2h after testing.
Shell resistance
: 10 mΩ max.
② No damage, crack and looseness of parts.
① Contact resistance : 70 mΩ max.
Corrosion Salt Mist
Exposed in 5 % salt water spray for 48 h.
Shell resistance
: 10 mΩ max.
② Insulation resistance : 25 MΩ min.
③ No heavy corrosion.
(Note 1) The operation temperature includes the temperature rise by current carrying.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
RI.TAKAYASU
AH.KODAMA
18.06.05
18.06.05
18.06.05
18.06.05
MO.SHIMOYAMA
MO.SHIMOYAMA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-122496-20-02
FI40-20S-CVS2(20)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
FORM HD0011-2-1
PART NO.
CODE NO
CL230-0536-9-20
0
△
1/2