APPLICABLE STANDARD
Operating
Storage
-40 C to 125 C
50 V AC / DC
0.5 A
-10 C to 50 C (Packed condition)
temperature range
temperature range
Operating or storage
humidity range
Applicable cable
(FPC/FFC)
RATING Voltage
Current
Relative humidity 90%MAX(Not dewed)
t = 0.3 ± 0.05 mm, Gold plating
Heat resistance : 125 C
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
×
×
×
×
Marking
ELECTRICAL CHARACTERISTICS
Contact resistance
1 mA (DC or 1000 Hz).
50 m MAX.
×
-
Including FPC/FFC bulk resistance (L = 8 mm)
Insulation resistance
Voltage proof
100 V DC.
500 M MIN.
×
×
-
-
150 V AC for 1 min.
No breakdown.
MECHANICAL CHARACTERISTICS
Mechanical operation
20 times insertions and extractions.
① Contact resistance : 50 m MAX.
② No damage, crack and looseness of parts.
① No electrical discontinuity of 1 s.
② Contact resistance : 50 m MAX.
③ No damage, crack and looseness of parts.
×
×
-
-
Vibration
Frequency 10 to 55 Hz, half amplitude
0.75 mm, for 10 cycles in 3 axial directions.
Shock
981 m/s2, duration of pulse 6 ms
at 3 times in 3 both axial directions.
×
×
-
-
FPC/FFC retention force Measured by applicable FPC/FFC.
(Connector, FPC/FFC at initial condition.
Direction of insertion : 0.4 × n N MIN.
(n : Number of contacts)
(note 1)
Thickness of FPC/FFC shall be t = 0.30 mm)
ENVIRONMENTAL CHARACTERISTICS
Rapid change of
temperature
Temperature -55→+15 to +35→+125→+15 to +35 C ① Contact resistance : 50 m MAX.
×
-
Time
30→ 2 to
3
→
30 → 2 to 3 min.
② Insulation resistance : 50 M MIN.
Under 1000 cycles.
③ No damage, crack and looseness of parts.
High temperature and high
humidity
Exposed at 60 ± 2 C,
Relative humidity 90 to 95 %, 1000 h.
×
×
-
-
1
△
Damp heat, cyclic
Exposed at -10 to +65 C,
Relative humidity 90 to 96 %,
10 cycles, Total 240 h.
① Contact resistance : 50 m MAX.
② Insulation resistance : 1 M MIN.
(At high humidity)
③ Insulation resistance : 50 M MIN.
(At dry)
④ No damage, crack and looseness of parts.
① Contact resistance : 50 m MAX.
② No damage, crack and looseness of parts.
Dry heat
Cold
Exposed at 125 ± 2 C, 1000 h.
Exposed at -55 ± 3 C, 1000 h.
×
×
×
-
-
-
Sulphur dioxide
Exposed at 40 ± 2 C, Relative humidity 80 ± 5 %,
25 ± 5 ppm for 96 h.
Contact resistance : 50 m MAX.
[JIS C 60068-2-42]
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
YT.NINOMIYA
CHECKED
HS.HIRAHARA
KN.SHIBUYA
HH.MURAKAMI
YT.NINOMIYA
YT.NINOMIYA
DATE
1
△
1
DIS-F-00020312
20240405
20211007
20211006
20211006
20211006
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-391183-01-00
FH75-**S-0.5SH(01)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1
△
1/2
CL580
FORM HD0011-2-1