APPLICABLE STANDARD
Operating
temperature range
Storage
-55C to 85C
-10C TO 50C
(packed condition)
temperature range
Operating or storage
humidity range
Voltage
Current
RATING
30V AC/DC
0.20A
90%MAX(not dewed)
Relative humidity
Applicable cable
t=0.2±0.02mm, gold plating
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General examination
Marking
Visually and by measuring instrument.
Confirmed visually.
×
×
×
×
According to drawing.
(note 1,2)
ELECTRICAL CHARACTERISTICS
Voltage proof
90V AC for 1 min.
No flashover or breakdown.
×
×
×
×
×
×
Insulation resistance
100V DC.
50M MIN.
300m MAX.
Including FPC bulk resistance (L=8mm)
Contact resistance
20mV AC MAX, 1mA.
MECHANICAL CHARACTERISTICS
Frequency 10 to 55 Hz, half amplitude 0.75 mm,
for 10 cycles in 3 axial directions.
981 m/s2, duration of pulse 6 ms at 3 times
in 3 both axial directions.
×
×
-
-
Vibration
① No electrical discontinuity of 1s.
② Contact resistance: 300m MAX.
③ No damage, crack and loose parts.
Shock
① Contact resistance: 300m MAX.
② No damage, crack and loose parts.
×
×
-
-
Mechanical operation
FPC retention force
10 times insertions and extractions.
Measured by applicable FPC.
(thickness of FPC shall be t=0.20mm at initial condition)
Direction of insertion: 12.34N MIN(note 3)
ENVIRONMENTAL CHARACTERISTICS
① Contact resistance: 300m MAX.
② No damage, crack and loose parts.
③ No evidence of corrosion which affects
connector’s operation.
×
×
-
-
Corrosion salt mist
Exposed at 35±2C, 5% salt water spray for 96h.
Temperature-55 → +15TO+35 →+85→+15TO+35C
Rapid change of
temperature
① Contact resistance: 300m MAX.
② Insulation resistance: 50M MIN.
③ No damage, crack and loose parts.
Time
Under 5 cycles.
Exposed at 40±2C,
30
→
2 TO 3 → 30→ 2 TO 3 min
Damp heat
(steady state)
×
×
-
-
relative humidity 90 to 95%, 96h.
① Contact resistance: 300m MAX.
② Insulation resistance: 1M MIN.
(at high humidity)
Exposed at -10 to +65C,
relative humidity 90 to 96%,
10 cycles, total 240h.
Damp heat,cyclic
③ Insulation resistance: 50M MIN.
(at dry)
④ No damage, crack and loose parts.
Dry heat
Cold
Exposed at 85±2C, 96h.
Exposed at -55±3C, 96h.
×
×
×
-
-
-
① Contact resistance: 300m MAX.
② No damage, crack and loose parts.
Exposed at 40±2C,
relative humidity 80±5%,
25±5ppm for 96h.
Sulphur dioxide
① Contact resistance: 300m MAX.
② No damage, crack and loose parts.
③ No evidence of corrosion which affects
connector’s operation.
[JIS C 60068-2-42]
Exposed at 40±2C,
relative humidity 80±5%,
10 to 15ppm for 96h.
×
-
Hydrogen sulphide
[JIS C 60068-2-43]
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
HY.YAMAZAKI
HY.YAMAZAKI
ST.YUDATE
20220907
20220907
20220907
20220907
Unless otherwise specified, refer to IEC 60512.
ST.YUDATE
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-391816-99-00
FH58SA-81S-0.2SHW(99)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1/2
CL0580-3825-0-99
△
FORM HD0011-2-1