APPLICABLE STANDARD
OPERATING
STORAGE
-55℃ TO +85℃
30V AC/DC
0.2 A
-10℃ TO +50℃(PACKED CONDITION)
TEMPERATURE RANGE
TEMPERATURE RANGE
OPERATING OR STORAGE
HUMIDITY RANGE
90%
RELATIVE HUMIDITY
MAX(NOT DEWED)
RATING VOLTAGE
CURRENT
APPLICABLE CABLE
t=0.2±0.02mm, GOLD PLATING
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
×
×
×
×
MARKING
ELECTRICAL CHARACTERISTICS
VOLTAGE PROOF
90V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
50MΩ MIN.
×
×
×
×
×
×
INSULATION RESISTANCE 100V DC.
CONTACT RESISTANCE
AC 20mV MAX (1KHz), 1mA.
200mΩ MAX.
INCLUDING FPC BULK RESISTANCE
(L=8mm)
MECHANICAL CHARACTERISTICS
VIBRATION
FREQUENCY 10 TO 55 Hz, HALF AMPLITUDE
① NO ELECTRICAL DISCONTINUITY OF 1μs.
② CONTACT RESISTANCE: 200mΩ MAX.
③ NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
×
×
×
-
-
-
0.75 mm FOR 10 CYCLES IN 3 AXIAL DIRECTIONS.
981 m/s2, DURATION OF PULSE 6ms AT 3 TIMES
IN 3 BOTH AXIAL DIRECTIONS.
SHOCK
MECHANICAL OPERATION 10 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 200mΩ MAX.
② NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
FPC RETENTION FORCE
MEASURED BY APPLICABLE FPC.
(THICKNESS OF FPC SHALL BE t=0.20mm
AT INITIAL CONDITION.)
DIRECTION OF INSERTION: 4 + 0.1×n N MIN.
(note 1)
×
×
-
-
ENVIRONMENTAL CHARACTERISTICS
CORROSION SALT MIST
EXPOSED AT 35±2℃, 5% SALT WATER SPRAY
① CONTACT RESISTANCE: 200mΩ MAX.
② NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
FOR 96h.
③ NO EVIDENCE OF CORROSION WHICH
AFFECTS TO OPERATION OF CONNECTOR.
① CONTACT RESISTANCE: 200mΩ MAX.
② INSULATION RESISTANCE: 50MΩ MIN.
③ NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55→+15 TO +35→+85→+15TO+35 ℃
×
×
-
-
TIME
30 →
2 TO 3 → 30 → 2 TO 3 min
UNDER 5 CYCLES.
DAMP HEAT
(STEADY STATE)
EXPOSED AT 40±2℃,
RELATIVE HUMIDITY 90 TO 95%, 96h.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
NF.MIYAZAKI
YN.TAKASHITA
YH.MICHIDA
NM.SANPEI
15.07.30
15.07.30
15.07.29
15.07.29
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-365495-00-00
FH43MW-**S-0.25SHW(10)
DRAWING NO.
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/2
CL580
FORM HD0011-2-1