APPLICABLE STANDARD
OPERATING
STORAGE
-55 C TO 105 C
50 V AC / DC
0.5 A
-10 CTO50C
(PACKEDCONDITION)
TEMPERATURE RANGE
TEMPERATURE RANGE
OPERATING OR STORAGE
HUMIDITY RANGE
RELATIVEHUMIDITY 90 %MAX(NOTDEWED)
RATING VOLTAGE
CURRENT
APPLICABLE CABLE
t=0.3±0.03mm, GOLD PLATING
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
ACCORDING TO DRAWING.
×
×
×
×
MARKING
CONFIRMED VISUALLY.
ELECTRICAL CHARACTERISTICS
VOLTAGE PROOF
250 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
×
×
×
×
INSULATION
RESISTANCE
100 V DC.
500 M MIN.
CONTACT RESISTANCE AC/DC 20 mV MAX ( AC:1 KHz ) , 1 mA .
100 m MAX.
×
×
INCLUDING FPC,FFC BULK RESISTANCE
(L=8mm)
MECHANICAL CHARACTERISTICS
FREQUENCY 10 TO 55 Hz, HALF AMPLITUDE
0.75 mm, FOR 10 CYCLES IN 3 AXIAL DIRECTIONS.
981 m/s2 , DURATION OF PULSE 6 ms
AT 3 TIMES IN 3 BOTH AXIAL DIRECTIONS.
VIBRATION
① NO ELECTRICAL DISCONTINUITY OF
1 s.
② CONTACT RESISTANCE: 100 m MAX.
③ NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
×
×
-
-
SHOCK
MECHANICAL
OPERATION
20 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 100 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
×
×
-
-
FPC RETENTION FORCE MEASURED BY APPLICABLE FPC.
(THICKNESS OF FPC SHALL BE t=0.30mm
AT INITIAL CONDITION.)
DIRECTION OF INSERTION :
(TOP CONTACT)
0.2N×NUMBER OF CONTACTS MIN.
(BOTTOM CONTACT)
0.3N×NUMBER OF CONTACTS MIN.
(note 1)
ENVIRONMENTAL CHARACTERISTICS
CORROSION SALT MIST
EXPOSED AT 35±2 ℃ , 5 % SALT WATER
SPRAY FOR 96 h.
① CONTACT RESISTANCE: 100 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
×
×
-
-
③ NO EVIDENCE OF CORROSION WHICH
AFFECTS TO OPERATION OF
CONNECTOR.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE-55→+15TO+35→
① CONTACT RESISTANCE: 100 m MAX.
② INSULATION RESISTANCE: 50 M MIN.
+105→+15TO+35C
2
TIME
30→ 2 TO
3
→ 30→ 2 TO 3 min ③ NO DAMAGE, CRACK AND LOOSENESS
UNDER 5 CYCLES.
OF PARTS.
DAMP HEAT
(STEADY STATE)
EXPOSED AT 40±2 C,
RELATIVE HUMIDITY 90 TO 95 %, 96 h.
×
×
-
-
DAMP HEAT,CYCLIC
EXPOSED AT -10 TO +65 C,
RELATIVE HUMIDITY 90 TO 96 %,
10 CYCLES,TOTAL 240 h.
① CONTACT RESISTANCE: 100 m MAX.
② INSULATION RESISTANCE: 1 M MIN.
(AT HIGH HUMIDITY)
③ INSULATION RESISTANCE: 50 M MIN.
(AT DRY)
④ NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
SE.YOKOYAMA
CHECKED
DATE
3
DIS-F-00005614
HS.HIRAHARA
20200611
2
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
MO.ISHIDA
HS.SAKAMOTO
YS.EBI
20131129
20131129
20131128
20131128
This product is RoHS compliant.
Unless otherwise specified, refer to IEC 60512.
NM.SANPEI
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC4-159714-04
PART NO.
CODE NO.
FH34SRJ-*S-0.5SH(50)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
2
△
1/2
CL580