FFM101 thru FFM107P
Surface Mount Glass Passivated Super Fast Rectifiers
Reverse Voltage 50 to 1000V Forward Current 1.0A
FEATURES
* Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
* High temperature metallurgically
bonded construction
* Cavity-free glass passivated junction
* Capable of meeting environmental standards
of MIL-S-19500
* Fast Switching for high efficiency
* Typical IR less than 1.0µA
* High temperature soldering guaranteed:
260°C/10 seconds
Mechanical Data
Case: JEDEC DO-214AC, molded plastic over glass body
Terminals: Plated axial leads, solderable per
MIL-STD-750, Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
We declare that the material of product compliance
with ROHS requirements
Weight: 0.0023 oz., 0.065 g
Handling precautin:None
1.Maximum & Thermal Characteristics Ratings at 25°C ambient temperature unless otherwise specified.
FFM
101
FFM
102
FFM
103
FFM
104
FFM
105
FFM
106
FFM
107
FFM
107P
Parameter Symbol
symbol
Unit
Device marking code
FF1
50
FF2
100
70
FF3
200
140
200
FF4
400
280
400
FF5
600
420
600
FF6
800
560
800
FF7
FF7P
VRRM
Maximum repetitive peak reverse voltage
Maximum RSM voltage
1000 1000
700 700
1000 1000
V
V
V
VRSM
VDC
35
Maximum DC blocking voltage
50
100
Maximum average forward rectified current
0.375" (9.5mm) lead length at TA = 75°C
1.0
IF(AV)
A
A
Peak forward surge current 8.3ms single half sine-
wave superimposed on rated load (JEDEC Method)
Typical thermal resistance (Note 2)
IFSM
30
75
RθJA
TJ, TSTG
°C/W
°C
–50 to +150
Operating junction and storage temperature range
Electrical Characteristics Ratings at 25°C ambient temperature unless otherwise specified.
FFM
101
FFM
102
FFM
103
FFM
104
FFM
105
FFM
106
FFM
107
FFM
107P
Parameter Symbol
symbol
VF
Unit
V
1.3
Maximum instantaneous forward voltage at 1.0A
5.0
100
Maximum DC reverse current TA = 25°C
at rated DC blocking voltage TA = 125°C
Typical reverse recovery time (Note 1)
Typical junction capacitance at 4.0V, 1MHz
NOTES:
IR
µA
150
500
trr
CJ
250
ns
PF
8.0
1. IF = 0.5A, IR = 1.0A, IRR = 0.25A
2. Thermal resistance from junction to ambient at 0.375” (9.5mm) lead length, P.C.B. mounted