• 10 WATTS OUTPUT POWER
• 2:1 AND 4:1 WIDE INPUT VOLTAGE RANGE
• INTERNATIONAL SAFETY STANDARD APPROVAL
• SIX-SIDED CONTINUOUS SHIELD
• HIGH EFFICIENCY UP TO 86%
• STANDARD 2” X 1” X 0.4” PACKAGE
• FIXED SWITCHING FREQUENCY
The FDC10 and FDC10-W series offer 10 watts of output power from a 2 x 1 x 0.4 inch
package. FDC10 series have 2ꢀ1 wide input voltage of 9-18, 18-36 and 36-75VDC.
FDC10-W series have 4:1 ultra wide input voltage of 9-36 and 18-75VDC. The FDC10 and
FDC10-W features 1600VDC of isolation, short-circuit and over-voltage protection, as well
as six sided shielding. The safety approval of EN60950 and UL1950. All models are
particularly suited to telecommunications, industrial, mobile telecom and test equipment
applications. According the extended operation temperature range, there are “M1” and “M2”
version for special application.
UL E193009
TUV R2054609
CB JPTUV-001422
CE MARK
T E C H N I C A L S P E C I F I C AT I O N All specifications are typical at nominal input, full load and 25ºC otherwise noted.
OUTPUT SPECIFICATIONS
Output power
GENERAL SPECIFICATIONS
Efficiency
10 Watts max
± 2%
See table
Voltage accuracy
Minimum load (Note 1)
Line regulation
Full load and nominal Vin
Isolation voltage
1600VDC, min
9
10% of FL
± 1%
Isolation resistance
Isolation capacitance
Switching frequency
Approvals and standard
Case material
10 ohms, min
LL to HL at Full Load
10% to 100% FL
300pF, max
300KHz, typ
Single
Dual
± 1%
± 2%
Load regulation
Cross regulation
Ripple and noise
IEC60950, UL1950, EN60950
Nickel-coated copper
Asymmetrical load 25% / 100% FL
± 5%
Single
50mVp-p
75mVp-p
20MHz bandwidth
Dual
Base material
Non-conductive black plastic
Epoxy (UL94-V0)
Temperature coefficient
I0.02% / ºC, max
Potting material
Transient response recovery time 25% load step change
500uS
2.00 X 1.00 X 0.40 Inch
(50.8 X 25.4 X 10.2 mm)
Dimensions
3.3V output
Over voltage protection 5V output
3.9V
6.2V
15V
18V
Weight
27g (0.95oz)
1.976 x 106 hrs
Zener diode clamp
12V output
15V output
MTBF (Note 4)
Over load protection
% of FL at nominal input
150% typ
ENVIRONMENTAL SPECIFICATIONS
Short circuit protection
Hiccup, automatics recovery
Standard
M1 (Note 5)
M2 (W series) -40ºC ~ +85ºC (with derating)
-25ºC ~ +85ºC (with derating)
-40ºC ~ +85ºC (non-derating)
Operating temperature range
(Reference derating curve)
INPUT SPECIFICATIONS
FDC10
12V nominal input
9 – 18VDC
18 – 36VDC
36 – 75VDC
9 – 36VDC
18 – 75VDC
Maximum case temperature
Storage temperature range
+100ºC
24V nominal input
48V nominal input
FDC10-W 24V nominal input
48V nominal input
Input voltage range
-55ºC ~ +105ºC
Nature convection
Nature convection with heat-sink 10ºC/watt
12ºC/watt
Thermal impedance (Note 6)
Input filter
Pi type
Thermal shock
Vibration
MIL-STD-810D
12V input
24V input
48V input
36VDC
50VDC
100VDC
Input surge voltage
100mS max
10~55Hz, 2G, 30minutes along X,Y and Z
5% to 95% RH
Relative humidity
Input reflected ripple (Note 2) Nominal Vin and full load
Start up time Nominal Vin and constant resistor load
30mAp-p
20mS typ
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD
EN55022
Level A
Level A
Remote ON/OFF (Note 3)
(Positive logic)
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
Short or 0V < Vr < 1.2V
Open or 3.5V < Vr < 12V
2.5mA
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
(Negative logic)
Radiated immunity
Fast transient
Surge
Remote off input current Nominal Vin
Conducted immunity