P O W E R T R A N S F O R M E R
P C M O U N T : SPLIT PACK
F48-050
Description:
The F48-050 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The output voltage will be either 48.0V with a
center-tap under a 0.05A load with the secondaries wired in series, or 24.0V
under a 0.1A load with the secondaries wired in parallel. The split bobbin design
eliminates the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 2.5VA
2. Primary:
115V
3. Secondary: Series: 48.0V CT@ 0.05A
Parallel: 24.0V @ 0.1A
W
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
E
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
L
This model is also available in Class 3, UL 5085-3 (1585) version as F48-050-C2
H
Dimensions:
Units in inches.
H
W
L
A
B
C
D
E
F
1
4
1.187 1.125 1.375 0.250 0.250 1.200 0.041 0.020 0.234
Weight: 0.25 lbs
D
F
Schematic:
5
A
A
1
5
8
115V
6
7
50/60Hz
B
4
8
C
RoHS Compliance: As of manufacturing date February 2016, all standard products meet
the requirements of 2015/863/EU, known as the RoHS 3 initiative.
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2
and 5085-3, respectively.
1
4
0.06" DIAMETER
HOLE
*Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics
website for the most current version. For soldering and washing information please see
http://www.triadmagnetics.com/faq.html
Board Layout
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: May 1, 2019