EXA40 Series
S i n g l e o u t p u t
• High efficiency topology, 91% typical at 5 V
• Approved to EN60950, UL1950, CSA C22.2 No. 950
• Operating ambient temperature of -40 °C to +70 °C
(natural convection)
• Complies with ETS 300 019-1-3/2-3
• Complies with ETS 300 132-2 input voltage and current
requirements
• Fully compliant with ETS 300 386-1
• RoHS Compliant
The EXA40 Series, comprising 8 different models is targeted specifically at the
telecommunications, industrial electronics, mobile Telecommunications and distributed
power markets. The series offers two wide input voltage ranges of 18 Vdc to 36 Vdc and
36 Vdc to 75 Vdc. Typical efficiencies are 91% for the 5 V output, 88% for the 3.3 V, 86%
for the 2.75 V and 84% for the 1.8 V. The series has been designed primarily for
Telecommunications applications and complies with ETS 300 386-1 immunity and emission
standards for high priority of service class. In addition the series complies with ETS 300
019-1-3 environmental standards (all classes) including shock, vibration, humidity and
thermal performance. A high level of reliability has been designed into all models through
the extensive use of conservative derating criteria. Remote enable and overtemperature
shutdown are included as standard while true latching OVP is available as an option.
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS (Cont.)
Radiated emissions
ESD air
EN55022 (See Design Note 102) Level B
EN61000-4-2, level 3
Voltage adjustability
(See Note 10)
2.75 V, 3.3 V, 5 V
10% min.
1.8 V output
+12/-17% min.
ESD contact
EN61000-4-2, level 4
Surge (500 V)
EN61000-4-5, level 3, 4
EN61000-4-4, level 3, 4
EN61000-4-3, level 3
Voltage accuracy
Line regulation
Load regulation
Minimum load
1.0%
+0.05%
+0.20%
0%
Fast transients
Radiated immunity
Conducted immunity
Low line to high line
Full load to no load
EN61000-4-6, level 3
GENERAL SPECIFICATIONS
Efficiency
See table
1500 Vdc
Ripple and noise
20 MHz bandwidth
100 mV pk-pk max.
20 mV rms max.
Basic insulation
Input/output
Input fuse 24 V
Input fuse 48 V
(See Note 8)
3.5 A slow blow
2.0 A slow blow
Temperature coefficient
0.01%/°C
Switching frequency
Fixed
300 kHz
Transient response
50% to 75% and back
100 mV
250 µs
Peak dev. settling time
to 1.0%, no external cap.
Approvals and
standards
(See Notes 7, 8, 9)
EN60950
UL1950
CSA C22.2 No. 950
Short circuit protection
(See Note 5)
Continuous
automatic recovery
Weight
25 g (0.88 oz)
250,000 hours
INPUT SPECIFICATIONS
MTBF
(See Design Note 102)
MIL-HDBK-217
Input voltage range
24 Vin nominal
48 Vin nominal
18-36 Vdc
36-75 Vdc
ENVIRONMENTAL SPECIFICATIONS
Input current
No load
Remote OFF
100 mA max.
4 mA max.
Thermal performance
Operating ambient
temperature
-40 °C to +70 °C,
See curves
Non-operating
-55 °C to +105 °C
UVLO turn ON voltage
All inputs (See Note 4)
94%
86%
UVLO turn OFF voltage All inputs (See Note 4)
Over temperature
shutdown
Loss of Function
Self-Recovery (LFS)
75 °C to +85 °C
Start-up time
Nominal line
50 ms
ETS 300 019-2-3
Air temperature
Classes T3.1 to T3.5
Active high remote ON/OFF
Logic compatibility
Low: IEC 68-2-1
High: IEC 68-2-2
Change: IEC 68-2-1
-40 °C
+70 °C
-40 °C to +70 °C
Open Collector
ref. to -input
4.5 Vdc
ON
OFF
Open circuit voltage
Relative humidity
IEC 68-2-56
IEC 68-2-30
10% to 100% RH
Condensation
<1.0 Vdc
INPUT SPECIFICATIONS
Vibration, Class 3M5
IEC68-2-6
2-9 Hz, 3 mm disp.
9-200 Hz 1 g
ETS 300 386-1 table 5
Conducted emissions
(See Design Note 102)
MIL-STD-202F
IEC-68-2-29
MIL-STD-202F
Method 204 cond. A
EN55022, internal filter and
two 4 µF film capacitors
EN55022, external filter
Level A
Level B
Shock, Class 3M5
Method 213B cond. A
File Name: exa40.pdf Rev (02): 09 Dec 2005