ER1000 THRU ER1004
SUPERFAST RECOVERY RECTIFIERS
VOLTAGE - 50 to 400 Volts CURRENT - 10.0 Amperes
FEATURES
Plastic package has Underwriters Laboratory
TO-220AC
l
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound
l
l
l
l
l
l
Exceeds environmental standards of MIL-S-19500/228
Low power loss, high efficiency
Low forward voltage, high current capability
High surge capacity
Super fast recovery times, high voltage
Epitaxial chip construction
MECHANICAL DATA
Case: TO-220AC molded plastic
Terminals: Lead, solderable per MIL-STD-202, Method 208
Polarity: As marked
Mounting Position: Any
Weight: 0.08 ounces, 2.24 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, Resistive or inductive load.
For capacitive load, derate current by 20%.
UNITS
ER1000
ER1001 ER1001A ER1002
ER1003
300
210
ER1004
400
320
V
V
V
A
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
50
35
50
100
70
100
150
105
150
200
140
200
300
400
Maximum Average Forward Rectified
Current at TC=100
Peak Forward Surge Current,
8.3ms single half sine-wave superimposed
on rated load(JEDEC method)
10
A
150
V
A
Maximum Forward Voltage at 10.0A per
element
Maximum DC Reverse Current at Rated Ta=25
DC Blocking Voltage per element Ta=125
0.95
35
1.30
10
500
62
PF
Typical Junction capacitance (Note 1)
ns
Maximum Reverse Recovery Time(Note 2)
Typical Thermal Resistance(Note 3) R JC
Operating and Storage Temperature Range TJ
50
/W
3.0
-55 to +150
NOTES:
1. Measured at 1 MHz and applied reverse voltage of 4.0 VDC
2. Reverse Recovery Test Conditions: IF=.5A, IR=1A, Irr=.25A