1-800-383-7323 / USA
1- 00- 8 -7323 / USA
EVEREADY BATTERY CO.
1-800-383-7323 / CANADA
1- 00- 8 -7323 / CANADA
Internet: www.energizer.com
+ 44 (0) 208 920 2306 / EUROPE
ENERGIZER NO. CR1216
Lithium / Manganese Dioxide (Li/MnO2 )
Chemical System:
Designation:
Battery Voltage:
Average Weight:
Volume:
IEC-CR1216
3.0 Volts
0.7 grams (0.02 oz.)
0.2 cubic centimeters (0.01 cubic inch)
Industry Standard Dimensions in mm (inches)
Average Capacity: 29 mAh to 2.0 volts
(Rated at 45k ohms continuous at 21ºC)
Maximum Reverse
Charge Current:
Energy Density:
1 microampere
118 milliwatt hr/g, 413 milliwatt hr/cc
TYPICAL DISCHARGE CURVE
Simulated Test @ 21ºC (70ºF)
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
0
100
200
300
400
500
Service, Hours
Simulated Application Test
Estimated Average Service at 21ºC (70ºF)
Typical Drains
at 2.9V
(microamperes)
Cutoff Voltage
2.0V
Load
(ohms)
Schedule:
24 hours/day
63
45,000
467 Hours
INTERNAL RESISTANCE CHARACTERISTICS
Pulse Test @ 21ºC (70ºF)
Schedule: Continuous for background
2 seconds X 12times/day for pulse
Typical Background Drain @ 2.9V (milliamps):
0.63 milliamperes
Typical Pulse Drain @ 2.6V (milliamps):
7.00 milliamperes
Background Load:
IR CHARACTERISTICS
Pulse Test @ 21ºC (70ºF)
3.0
2.8
2.6
2.4
2.2
2.0
1.8
175
BKGND
PULSE
150
125
100
75
IR
50
45k ohms
25
Pulse Load:
0
4
8
12
16
20
24
28
32
400 ohms
Capacity, mAh
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
Form No. EBC - 4112D