EML
MAIN FEATURE
1. High switching current at 16A in small size.
2. 1 N/O contact with a Tungsten pre-make contact.
3. Dielectric Strength up to 5,000VAC.
4. 1 pole 16 A, 1 NO contact
(W pre-make contact + AgSnO2).
165 A / 20 ms inrush peak current.
5. Comply with RoHS and REACH regulations.
CONTACT RATING
Load Type
Rated Load (Resistive)
Rated Carrying Current
Max. Allowable Voltage
Max. Allowable Current
Max. Allowable Power Force
Contact Material
EML (DM)
16A 277VAC
16A
AC 400V
16A
4000VA
R (Main) : Ag Alloy, L (Pre-make) : W
Tungsten Load: 3000W/230VAC
SPST
Contact Capacity
Contact Form
APPLICATION
Humidity Range..................... 45~85% RH.
Temperature Range..............-45~ 85°C.
Lamp Control, Audio Equipment, Domestic
Appliance and Controlling Equipment…etc.
Coil Temperature Rise.......... 45°C Max.
Shock:
Destruction ........................... 1,000 m/S2
Malfunction .......................... 100 m/S2
PERFORMANCE (AT INITIAL VALUE)
Contact Resistance.......... 100 m Max.@1A,6VDC
Contact Rating(resistive load)
Operate Time ................... 10 mSec. Max.
Release Time ................... 5 mSec. Max.
Dielectric Strength:
Life Expectancy:
Electrical ................................ 6x104 Operations at
Rated Resistive Load
3x104 Operations at
Tungsten Load
Between Coil & Conta...c.t.... 5,000VAC at 50/60Hz
for one minute
Mechanical............................. 5x106 Operations at
Between Contacts ........... 1,000VAC at 50/60Hz
for one minute
Surge Strength................. 10,000V (between coil
& contact 1.2x50uSec.)
No Load condition
Weight.................................... About 12.5 g
Insulation Resistance ...... 100M Min. at
500VDC
ACCESSORIES & SOCKETS
Max. On/Off Switching:
PI-50BE ................................ See Page 171
PI-50BE/3 ............................. See Page 171
PI-50-0.................................. See Page 173
Electrical........................... 6 Cycles per Minute
Mechanical ....................... 300 Cycles per Minute
Vibration:
Destruction
10 to 55 to 10 Hz,0.75 mm single
......................
amplitude (1.5mm double amplitude)
SAFETY STANDARD & FILE NUMBER
Malfunction
......................
10 to 55 to 10 Hz,0.75 mm single
amplitude (1.5mm double amplitude)
UL........................................E141060
80