2
APPLICABLE STANDARD
TÜV approved(R 50362678)
UL approved (E52653)
1
OPERATING TEMPERATURE
-20 C TO +90 C
(Including temperature rise due to
conduction)
STORAGE TEMPERATURE
RANGE
-10 C TO +60 C
RANGE
RATING
AC 600 V , DC 750 V(TÜV、UL)
1
VOLTAGE
CURRENT
2
AC,DC 1,000V
Applicable Cable
1
1
1
1
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
MARKING
ELECTRIC CHARACTERISTICS
X
X
CONTACT RESISTANCE
MEASURED AT THE CONTACT AT DC 1A.
0.5mΩ MAX.
X
X
X
X
INSULATION RESISTANCE
VOLTAGE PROOF
MEASURED AT DC 500V.
1000MΩ MIN.
AC 2200V APPLIED FOR 1min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONNECTOR INSERTION AND
MEASURED WITH AN APPLICABLE CONNECTOR
INSERTION AND WITHDRAWAL FORCES: 200N MAX.
NO DAMAGE
X
X
―
―
WITHDRAWAL FORCES
WITHOUT A LOCKING DEVICE.
TERMINAL RETENTION FORCE
MECHANICAL OPERATION
280N APPLIED AT THE CONNECTION
1) NO FUNCTION IMPAIRING DAMAGE, CRACKS, OR
LOOSENESS IN THE PARTS.
2) CONTACT RESISTANCE: 1 mΩ MAX.
INSERETED AND EXTRACTED 50 TIMES.
X
―
FREQUENCY RANGE: 10 TO 500Hz/CYCLE,SINGLE AMPLITUDE OF 1) NO ELECTRICAL DISCONUITY OF 10μs.
VIBRATION
SHOCK
0.75mm, FOR 3 HOURS IN 3 AXIAL DIRECTIONS
(MIL-STD-1344 method 2005, condition 2).
IN 6 AXIAL DIRECTIONS AT AN ACCELERATION OF 490 m/s2, 1) NO ELECTRICAL DISCONUITY OF 10μs.
2) NO DAMAGE, CRACKS, OR LOOSENESS IN THE
PARTS.
X
X
―
―
A PULSE DURATION OF 11ms AND PERFORMED 3 TIMES.
2) NO DAMAGE, CRACKS, OR LOOSENESS IN THE
PARTS.
ENVIRONMENTAL CHARACTERISTICS
1) INSULATION RESISTANCE: 10MΩ MIN (WHEN
WET).
DAMP HEAT
2) INSULATION RESISTANCE: 100MΩ MIN (WHEN
DRY).
TEMPERATURE: 40゚ C, HUMIDITY 90 TO 95%,
LEFT FOR 96 HOURS.
X
X
―
―
(STEADY STATE)
3) NO DAMAGE, CRACKS, OR LOOSENESS IN THE
PARTS.
TEMPERATURE: -40゚ C → R/T(3) → +105゚ C → R/T
1) INSULATION RESISTANCE: 1000MΩ MIN.
2) NO DAMAGE, CRACKS, OR LOOSENESS IN THE
PARTS.
TEMPERATURE CYCLE
TIME: 30 → 2 TO 3 → 30 → 2 TO 3 min
TESTED OVER 5 CYCLES.
X
X
RESISTANCE TO HEAT
RESISTANCE TO COLD
EXPOSED AT A TEMPERATURE OF +105゚ C FOR 96 HOURS.
EXPOSED AT A TEMPERATURE OF -40゚ C FOR 96 HOURS.
NO DAMAGE, CRACKS, OR LOOSENESS IN THE PARTS.
NO DAMAGE, CRACKS, OR LOOSENESS IN THE PARTS.
―
―
CONNECTED TO AN APPLICABLE CONTACT AT A WATER DEPTH OF
1m FOR 30 MINUTES.
SEALING(2)
NO WATER PENETRATION INSIDE THE CONNECTOR.
X
―
CONNECTED TO AN APPLICABLE CONTACT, 17.6kPa OF AIR
PRESSURE WAS APPLIED FOR 30 SECONDS.
AIR TIGHTNESS(2)
NO AIR BUBBLES EMITTED FROM THE CONNECTOR.
NO FUNCTION IMPAIRING CORROSION.
X
X
―
―
CORROSION SALT MIST
CONCENTRATION 5% SALT WATER, LEFT FOR 48 HOURS.
3
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
WR.AJIRO
CHECKED
DATE
3
5
DIS-C-00002977
TP.KOMATSU
20190305
△
Notes: (1)
REMARKS
APPROVED
CHECKED
DESIGNED
SU.OBARA
YH.YAMADA
YS.SAKODA
20151217
20151217
20151217
Above specifications show the values in assembled condition with
applicable crimp contacts.
(2) Sealing and air tightness were tested under mated condition with an
applicable connector, and SANKEI CO.,LTD KEIGLAND E2KD 2836 ,E2KD 3236 or
E2KD 3636 installed.
3
(3) R/T = room temperature
DRAWN
THOMAS FORAN
20151217
For unspecified specifications, refer to IEC 60512 (JIS C 5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-118665-00-00
EM52M-WBR-4SCA
SPECIFICATION SHEET
3
1/3
HIROSE ELECTRIC CO., LTD.
△
CL138-0036-9-00
FORM HD0011-2-1