60W Single Output Class 2 Switching Power Supply
ELN-60 series
Features :
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled
Fully isolated plastic case with IP64 level
Class
power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.9)
100% full load burn-in test
Low cost, high reliability
2 years warranty
IP64
( for 48V only)
( except for 48V )
LPS
SPECIFICATION
MODEL
ELN-60-9
ELN-60-12
ELN-60-15
ELN-60-24
ELN-60-27
ELN-60-48
DC VOLTAGE
9V
12V
15V
24V
27V
48V
LED OPERATION VOLTAGE Note.8 3 ~ 9V
6 ~ 12V
5A
7.5 ~ 15V
4A
12 ~ 24V
2.5A
13.5 ~ 27V
2.3A
24 ~ 48V
1.3A
RATED CURRENT
CURRENT RANGE
RATED POWER
5A
0 ~ 5A
45W
0 ~ 5A
60W
0 ~ 4A
0 ~ 2.5A
60W
0 ~ 2.3A
62.1W
0 ~ 1.3A
62.5W
60W
RIPPLE & NOISE (max.) Note.2 120mVp-p
120mVp-p
10.8 ~ 13.2V
150mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
200mVp-p
24.3 ~ 29.7V
250mVp-p
43.2 ~ 52.8V
8.7 ~ 10.5V
OUTPUT
VOLTAGE ADJ. RANGE Note.7
Can be adjusted by internal potentiometer SVR1
CURRENT ADJ. RANGE Note.7 -25% ~ 3%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE Note.3 5.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
2.0%
Note.6 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms/230VAC
Note.4 90 ~ 264VAC
47 ~ 63Hz
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT
82%
85%
86%
87%
87%
88%
INPUT
1.2A/115VAC 0.7A/230VAC
COLD START 60A/230VAC
0.25mA / 240VAC
95 ~ 110%
OVER CURRENT
OVER VOLTAGE
Protection type : Constant current limiting, recovers automatically after fault condition is removed
11 ~ 13.5V 13.8 ~ 16V 17.5 ~ 21V 28 ~ 32V 31 ~ 35V
PROTECTION
54 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
FUNCTION DIMMING CONTROL (OPTIONAL)
WORKING TEMP.
WORKING HUMIDITY
-40 ~ +80 , 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
I/P-O/P:3KVAC
SAFETY &
EMC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
EMC IMMUNITY
MTBF
603Khrs min. MIL-HDBK-217F (25
181*61.5*35mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.4Kg; 24pcs/11Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
9. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:ELN-60-SPEC 2012-03-20