1-800-383-7323 / USA
EVEREADY BATTERY CO.
1-800-383-7323 / CANADA
Internet: www.energizer.com
ENERGIZER NO. 223 (EL223)
Chemical System:
Lithium
Lithium/Manganese Dioxide (Li/MnO2)
Designation:
Battery Voltage:
Average Weight:
Volume:
ANSI / NEDA-5024LC, IEC-CP-P2
6.0 Volts
37.0 grams (1.3 oz.)
Industry Standard Dimensions in mm (inches)
23.8 cubic centimeters (1.4 cubic inch)
Average Capacity: 1400 mAh to 4.0 volts
(Rated Capacity at 200 ohms at 21ºC)
Maximum Reverse
Charge Current:
Max Discharge:
Cells:
2 microampere
1500 mA continuous - 3500 mA pulse
Two 2/3A
Typical Discharge Characteristics
Schedule: 3 sec ON / 27 sec OFF
Typical Drain: 900 milliamperes
6.5
6.0
5.5
5.0
4.5
4.0
3.5
3.0
20ºC
-20ºC
0
400
800
Cycles
1200
1600
2000
This battery Contains a Positive Temperature
Coefficient (PTC) Device to Limit Current Flow
Typical Discharge Characteristics
Schedule: 3 sec ON / 7 sec OFF
Typical Drain: 1200 milliampere
6.5
6.0
5.5
5.0
4.5
4.0
3.5
3.0
Simulated Application Test
Estimated Average Service at 21ºC (70ºF)
20°C
Typical
Drains
(mA)
Cutoff Voltage
3.1 V 2.6 V
Load
(ohms)
4.0 V
Hours
Schedule:
24 hours/
day
Cycles
-
200
54.1
-
-
-
24 hours/
day
1000
900
-
-
-
1.4
-
-
3 sec ON /
7 sec OFF
3 sec ON /
27 sec OFF
-
-
1425
-
0
300
600
Cycles
900
1200
1500
1200
1800
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
Form No. EBC - 4205E
Page 1 of 1