INFRARED GAS ANALYZER FOR STACK GAS  
DATA SHEET  
ZSU-5  
This analyzer consists of an infrared gas analyzer, an O2 sen-  
sor and a gas sampling device. It is used for simultaneous  
and continuous measurement of the NOX, SO2, CO, CO2 and  
O2 components in the flue gas of various boilers, garbage  
incinerators, etc.  
For CO and O2 measurement specifications, the function for  
coping with the Japanese regulation on dioxin emission is  
incorporated.  
FEATURES  
1. Gas concentrations of 5 components is measurable simul-  
taneously and continuously  
NOx, SO2, CO and CO2 gas concentration measurements  
are integrated by infrared method, to which a zirconia or  
magnetic type O2 sensor is added for O2 measurement.  
Therefore, the gas concentrations of 5 components are  
simultaneously and continuously measurable.  
2. The use of highly sensitive and reliable mass flow detec-  
tor allows the range ratio of up to 1:25 with the standard 2  
range.  
3. Maintenance can be performed from the front side, thus  
saving the installation space.  
Unitized structure of the analyzing block and gas sampling  
module enables better maintenance.  
Analog output signals :  
Simultaneous output of signals of 4 to  
20 mA DC each (non-isolated or isolated  
depending on customers code selec-  
tion)  
4.Provided with abundant functions including O2 correc-  
tion output, average value output, automatic calibration,  
CO peak count alarm, automatic range changeover, and  
alarms.  
Five instantaneous value outputs (NOX,  
SO2, CO, CO2 and O2)  
Three instantaneous values (NOX, SO2,  
CO) after O2 correction when provided  
with O2 sensor  
Three average values (NOX, SO2, CO) af-  
ter O2 correction when provided with O2  
sensor  
5.N2O and CH4 can also be measured as an optional feature.  
Having warming effect 300 times as high as that of CO2,  
N2O is the greenhouse gas most controversial now.  
SPECIFICATIONS  
1. Standard Specifications  
Measuring system :  
Allowable load resistance :  
550 Ω or less (750 Ω or less for isolated  
output)  
NOx, SO2, CO and CO2 ; Ndir type infra-  
red  
O2 ; Zirconia type, magnetic type  
Measurable component and min./max. measurement  
Contact output: (1)Each 1a contact (contact capacity  
250 V AC, 2 A or 30 V DC, 3 A) for:  
Range identification of each component  
(Close/1st range) , analyzing block error,  
calibration error, auto calibration status,  
maintenance status,and CO peak count  
alarm  
range :  
NOX ; 0 to 50ppm/0 to 5000ppm  
SO2 ; 0 to 50ppm/0 to 5000ppm  
CO ; 0 to 50ppm/0 to 5000ppm  
CO2 ; 0 to 10%/0 to 20%  
O2 ; 0 to 10%/0 to 25%  
N2O and CH4 can be measured as an  
optional feature.  
(2)Each 1c contact (contact capacity 250V  
AC, 1 A or 30 V DC, 1 A) for:  
Concentration alarm for each compo-  
nents instantaneous value (H, L, HL  
settable), analyzing block power off  
Number of measurement ranges :  
2 Maximum range ratio: 1:25 (Refer to  
Code Symbols.)  
Warm-up time : Within 4 hours after power-on  
EDS3-138b  
Date Jun. 30, 2011  

与EDS3-138B相关器件

型号 品牌 描述 获取价格 数据表
EDS3-139B FUJI IN-SITU ZIRCONIA OXYGEN ANALYZER FOR HAZARDOUS LOCATION

获取价格

EDS3-141A FUJI NDIR TYPE INFRARED GAS ANALYZER(3-COMPONENT ANALYZER)

获取价格

EDS3-143 FUJI INFRARED GAS ANALYZER

获取价格

EDS3-144 FUJI INFRARED GAS ANALYZER(HIGH PERFORMANCE MODEL)

获取价格

EDS3-145 FUJI INFRARED GAS ANALYZER(LOW-CONCENTRATION MEASUREMENT TYPE)

获取价格

EDS-316 MOXA 16-port unmanaged Ethernet switches

获取价格