描述
COMPACT TYPE GAS ANALYZER

EDS3-130F 数据手册

 浏览型号EDS3-130F的Datasheet PDF文件第2页浏览型号EDS3-130F的Datasheet PDF文件第3页浏览型号EDS3-130F的Datasheet PDF文件第4页浏览型号EDS3-130F的Datasheet PDF文件第5页浏览型号EDS3-130F的Datasheet PDF文件第6页浏览型号EDS3-130F的Datasheet PDF文件第7页 
COMPACT TYPE GAS ANALYZER  
DATA SHEET  
ZSVF  
OVERVIEW  
The compact type gas analyzer (ZSVF) consists of an ana-  
lyzing block (infrared sensor and oxygen sensor) and a sam-  
pling block.  
For gas extractor, either simplified measurement (non-fixed  
type) or continuous measurement (fixed type) probe is se-  
lectable at option.  
Because a single beam type high-sensitivity mass flow sen-  
sor is adopted for the infrared sensor, long-term stability  
and maintainability are excellent.  
This analyzer is capable of simultaneously measuring max.  
5 components among NOx, SO2, CO2, CO, CH4 and O2 in  
sample gas, and is used for flue gas from stationary emis-  
sion sources such as various boilers, garbage incinerators  
and heat treatment furnaces, and for plant cultivation and  
research-purpose chemical analysis.  
FEATURES  
1. Gas concentrations of 5 components measurable simul-  
taneously and continuously (Note).  
SPECIFICATIONS  
Standard Specifications  
Concentrations of max. 4 gas components among NOx,  
SO2, CO2, CO and CH4 are continuously measurable with  
the infrared sensor, and that of O2 is continuously mea-  
surable with a magnetic force or galvanic cell type oxy-  
gen sensor in combination with a full-fledged sampling  
block.  
• Measuring system:  
NOx, SO2, CO2, CO and CH4; Non-disper-  
sive infrared absorption method with  
single light source and single beam (single  
beam method)  
2. Standard with 3-range analyzer  
Measurement can be performed over a broad range us-  
ing the range selector key.  
3. Compact type small and easy to use.  
O2; Magnetic force or galvanic cell method  
• Measurable component and min./max. measuring range:  
NOx; 0 to 500 ppm / 0 to 5000 ppm  
SO2; 0 to 500 ppm / 0 to 1 %  
CO2; 0 to 200 ppm / 0 to 100 %  
CO; 0 to 200 ppm / 0 to 100 %  
CH4; 0 to 1000 ppm / 0 to 100 %  
O2; 0 to 5 % / 0 to 25 %  
Max. 5 components measurable includ-  
ing O2  
• Number of measuring ranges:  
3 ranges  
The analyzing block and sampling block are separated from  
each other to facilitate transport and installation.  
Operation is easier because operation keys and display  
unit are all gathered in the analyzing block.  
4. A rich variety of standard functions incorporated.  
Auto zero calibration and auto drain discharge function  
are incorporated for ensuring an excellent maintainabil-  
ity.  
Max. 8-channel outputs are allowed including instanta-  
neous concentration value, O2-corrected value, O2-cor-  
rected moving average value and CP calculation value  
outputs.  
• Max. range ratio 1:5  
• Warm-up time: 30 min after power-on  
Provided with count-down timer indicat-  
ing function.  
• Analog output: In up to 8 channels.  
4 to 20 mA DC or 0 to 1 V DC (linear)  
Non-isolated output  
(Note) To perform measurement continuously, the standard  
requirements for sample gas (shown on page 3) need  
to be met, and periodic draining, zero/span calibra-  
tions and membrane filter replacement are required.  
Allowable load; 4 to 20 mA DC, 550or  
less  
0 to 1 V DC, 100 kor  
more  
This product is not explosion-proof. When handling dangerous gas, adequate attention shall be paid.  
EDS3-130f  
Date  
Apr. 1, 2011  

与EDS3-130F相关器件

型号 品牌 描述 获取价格 数据表
EDS3-132C FUJI COMPACT TYPE GAS ANALYZER

获取价格

EDS3-133F FUJI INFRARED GAS ANALYZER

获取价格

EDS3-134A FUJI INFRARED GAS ANALYZER FOR HEAT TREATMENT FURNACES

获取价格

EDS3-135E FUJI cross stacK laser Gas analYZer

获取价格

EDS3-136 FUJI INFRARED GAS ANALYZER FOR STIC GAS

获取价格

EDS3-138B FUJI INFRARED GAS ANALYZER FOR STACK GAS

获取价格