Panel Meters and Controllers
Panel Meter Modular
Series EDM 35
• Modular digital panel meter, 3 1/2-digit
• Indicating or controlling current, voltage,
resistance, temperature, tacho or frequency.
• Easy programming
• Programmable hysteresis and time delay
(up to 2 setpoints)
• Data hold
• Peak/valley function
• Password protection of programming parameters
• Stock-saving - several ranges on each input module
• IP 65 (front)
• Optional hardware lock of programming
• Optional high-efficiency red or green display
Product Description
Ordering Key
EDM35V1D41XXX
The EDM 35 is a 3 1/2-digit, ming itself is very user-friend- Main unit
modular digital panel meter ly. Furthermore, the EDM 35 Range
where input and output mo- includes peak/valley function Power supply
dules can be combined to suit and password protection. The Relay output
many applications. Scaling housing is easy to mount and Signal output
and setpoints are fully pro- ensures a protection degree Options
grammable and the program- of IP 65.
Type Selection
Range AC Voltmeters:
Range DC Voltmeters:
Range Ohmmeters:
Range DC Ammeters:
V1A: 0 to 199.9 mV
V2A: 0 to 1.999 V
V3A: 0 to 19.99 V
V4A: 0 to 199.9 V
V5A: 0 to 600 V *
V1D: -199.9 to +199.9 mV
V2D: -1.999 to +1.999 V
V3D: -19.99 to +19.99 V
V4D: -199.9 to +199.9 V
V5D: -600 to +600 V *
R1D: 0 to 199.9 Ω
R2D: 0 to 1.999 kΩ
R3D: 0 to 19.99 kΩ
R4D: 0 to 199.9 kΩ
A1D: -199.9 to +199.9 µA
A2D: -1.999 to +1.999 mA
A3D: -19.99 to +19.99 mA
A4D: -199.9 to +199.9 mA
A5D: -1999 to +1999 mA
A6D: -5.00 to +5.00 A
A7D: -10.00 to +10.00 A
* Nominal voltage according to IEC 60664-1.
The measuring range includes 15% tolerance equal to 690 V.
Range AC Ammeters:
Range Thermometers:
Pt 100:
Signal Output:
Options:
A1A: 0 to 199.9 µA
A2A: 0 to 1.999 mA
A3A: 0 to 19.99 mA
A4A: 0 to 199.9 mA
A5A: 0 to 1999 mA
A6A: 0 to 5.00 A
X: None
XX:
None
P1C:
P2C:
P1F:
P2F:
P3F:
-100.0 to 199.9°C
-100 to 850°C
-148.0 to 199.9°F
-148 to 392°F
1: 4 to 20 mA
CX: High eff. red display
DX: Green display
2: 0 to 20 mA
4: 0 to 10 V
XP:
Program lock
5: Transducer power
supply 12 VDC
6: Transducer power
supply 24 VDC
Contact factory for other out-
put signals
01-99: Special options
-148 to 1562°F
(assigned by factory)
A7A: 0 to 10.00 A
Thermocouple Type J:
-JC:
-JF:
-100 to 760°C
-148 to 1400°F
Thermocouple Type K:
-KC:
-KF:
-100 to 1250°C
-148 to 1999°F
Relay Output:
Power Supply:
Range Frequency Meters:
0: None
1: 1 Relay
2: 2 Relays
3: 12 to 48 VDC
4: 230 VAC
5: 115 VAC
6: 48 VAC
7: 24 VAC
F1X*: 5.0 to199.9 Hz
F2X*: 10.0 to 1999 Hz
*
Replace X with:
for Namur input
A
B for NPN, PNP
& Contact input
C 600 VAC input
Specifications are subject to change without notice (27.10.99)