Timers
Symmetrical Recycler
Type ECS
• Fail-safe two-wire connection
• Low-cost
• Multi-voltage: 24-230 VAC
• 2 types: Recycler (Start OFF)
Recycler (Start ON)
• Time range: 0.5 s - 10 m
• Knob-adjustable time setting
• Output: SCR 10-500 mA (screws) and SCR 10-700mA
(Fast-ON)
• For mounting on DIN-rail in accordance with
DIN/EN 50 022
• 22.5 mm small Euronorm housing
SCREW
FASTON
Product Description
Small, low cost monofunc- face by screw. The timer is
tion timer with adjustable used e.g. with industrial
time setting. 2-wire connec- relays or 3-phase contactors.
tion for easy and fail-safe use
Ordering Key
Housing
Function
Small E-line
Output
Power supply
Type
ECS S M23 A 10S F
(see diagram). For mounting
on DIN-rail or directly on sur-
Time range
Fast-ON connection
Type Selection
Mounting
Output
Time range
0.5 - 10 s
0.1 - 1 m
1 - 10 m
Connection
Screws
Supply: 24 - 230 VAC
For DIN-rail
or for screw
SCR
ECS S M23 A 10S (OFF)
ECS S M23 B 10S (ON)
SCR
Screws
ECS S M23 A 1M
ECS S M23 B 1M
(OFF)
(ON)
SCR
Screws
ECS S M23 A 10M (OFF)
ECS S M23 B 10M (ON)
For DIN-rail
or for screw
SCR
SCR
SCR
0.5 - 10 s
0.1 - 1 m
1 - 10 m
Fast-ON
Fast-ON
Fast-ON
ECS S M23 A 10S F (OFF)
ECS S M23 B 10S F (ON)
ECS S M23 A 1M F (OFF)
ECS S M23 B 1M F (ON)
ECS S M23 A 10M F (OFF)
ECS S M23 B 10M F (ON)
Time Specifications
Time ranges
10 S
Output Specifications
Output
SCR
0.5 - 10 s
0.1 - 1 m
Output current
Maximum load current
1 M
10 M
1
- 10 m
(screw terminals)
500 mA
700 m
(Fast-ON connection)
Maximum current for 100 ms
(screw terminals)
(Fast-ON connection)
Minimum load current
Time range accuracy
Max. setting: actual time
≥ max. set time
min. setting: actual time
≤ min. set time
5.5 A
7 A
10 m
Repeat accuracy
Time variation
Within rated power supply
and ambient temperature
≤ 0.2%
Leakage current
≤ 3.5 mA @ 230 V
typ.: 2 m
≤ 0.1%/V
≤ 0.2%/°C
Voltage drop
≤ 8 VAC
typ.: 5 VAC @ 50 mA
Ratio TOFF/TON
TOFF
1 ≤
≤ 1.1
TON
Supply Specifications
Reset
Time and output
Power supply interruption
≥ 200 ms
Power supply
Overvoltage cat. III (IEC 60664)
Rated operational voltage
(IEC 60038)
24-230 VAC, -10/+15%
None
Rated insulation voltage
Specifications are subject to change without notice (24.07.06)