5秒后页面跳转
ECS21BC PDF预览

ECS21BC

更新时间: 2024-11-30 14:56:23
品牌 Logo 应用领域
力特 - LITTELFUSE /
页数 文件大小 规格书
3页 407K
描述
工作原理 Input voltage must be supplied at all times for proper operation. When a fault is sensed thro

ECS21BC 数据手册

 浏览型号ECS21BC的Datasheet PDF文件第2页浏览型号ECS21BC的Datasheet PDF文件第3页 
Protection Relays  
Current Monitoring Relays and Transducers  
ECS SERIES  
Current Sensors  
Description  
The ECS Series of single-phase AC current sensors is a universal,  
overcurrent or undercurrent sensing control. Its built-in toroidal  
sensor eliminates the inconvenience of installing a stand-alone  
current transformer. Includes onboard adjustments for current  
sensing mode, trip point, and trip delay. Detects over or  
undercurrent events like locked rotor, loss of load, an open heater  
or lamp load, or proves an operation is taking place or has ended.  
Operation  
Input voltage must be supplied at all times for proper operation.  
When a fault is sensed throughout the trip delay, the output  
relay is energized. When the current returns to the normal run  
condition or zero, the output and the delay are reset. If a fault is  
sensed and then corrected before the trip delay is completed,  
the relay will not energize and the trip delay is reset to zero.  
Adjustment  
Select the desired function, over or under current sensing.  
Set the trip point and trip delay to approximate settings. Apply  
power to the ECS and the monitored load. Turn adjustment and  
watch the LED. LED will light; turn slightly in opposite direction  
until LED is off. Adjustment can be done while connected to the  
control circuitry if the trip delay is set at maximum. To increase  
sensitivity, multiple turns may be made through the ECSs  
toroidal sensor. The appropriate trip point range is determined by  
multiplying the amperage load by the number of turns/passes  
through the toroidal sensor. When using an external CT, select  
a 2VA, 0-5A output CT rated for the current to be monitored.  
Select ECS adjustment range 0. Pass one secondary wire  
lead through the ECS toroid and connect the secondary leads  
together.  
Wiring Diagram  
V = Voltage  
I> = Overcurrent  
I< = Undercurrent  
W = Insulated Wire Carrying  
Monitored Current  
Relay contacts are isolated.  
Arrow on the toroid points  
toward the load.  
Features & Benefits  
FEATURES  
BENEFITS  
Eliminates need to install stand-alone  
current transformer and provides isolation from  
monitored circuit  
Built-in toroidal  
current sensing  
Encapsulated  
Protects against shock, vibration, and humidity  
Adjustable mode, trip  
point and trip delay  
Provides flexibility for use in many applications  
10A, SPDT isolated  
relay output  
Allows control of AC voltage loads  
Ordering Information  
See next page.  
Accessories  
P1015-13 (AWG 10/12), P1015-64 (AWG 14/16),  
P1015-14 (AWG 18/22) Female Quick Connect  
These 0.25 in. (6.35 mm) female terminals are  
constructed with an insulator barrel to provide  
strain relief.  
© 2018 Littelfuse Protection Relays & Controls  
www.littelfuse.com/ecs  
RReevv:: 11--AA--016021721168  

与ECS21BC相关器件

型号 品牌 获取价格 描述 数据表
ECS-21K12A ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K12B ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K12C ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K12D ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K15A ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K15B ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K15C ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K15D ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K15E ECS

获取价格

MONOLITHIC CRYSTAL FILTERS
ECS-21K30A ECS

获取价格

MONOLITHIC CRYSTAL FILTERS