DATA SHEET
SEMICONDUCTOR
E2A THRU E2J
SURFACE MOUNT SUPERFAST RECTIFIER
VOLTAGE - 50 to 600 Volts CURRENT - 2.0 Ampere
SMF Unit: inch ( mm )
FEATURES
0.195 (0.9)typical
‧ For surface mounted applications
‧ Low profile package
‧ Built-in strain relief
‧ Easy pick and place
‧ Superfast recovery times for high efficiency
‧ Plastic package has Underwriters Laboratory
Flammability Classification 94V-O
‧ Glass passivated junction
(0.189)4.8
(0.173)4.4
5
0.22
0.15
(0.052)1.3
(0.043)1.1
‧ High temperature soldering:
260 O / 10 seconds at terminals
C
‧ High temperature soldering : 260OC / 10 seconds at terminals
‧ Pb free product at available : 99% Sn above meet RoHS
environment substance directive request
Z
5
Cathode Band
Top View
Detail
Z
enlarged
0.110(2.8)
0.095(2.4)
1.43
1.38
MECHANICAL DATA
0.10 max
‧ Case: JEDEC DO-214AC molded plastic
‧ Terminals: Solder plated, solderable per
MIL-STD-750, Method 2026
3.6
3.2
‧ Polarity: Indicated by cathode band
‧ Standard packaging: 12mm tape (EIA-481)
‧ Weight: 0.002 ounce, 0.064 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25O
ambient temperature unless otherwise specified.
C
Single phase, half wave 60Hz resistive or inductive load.
For capacitive load, derate current by 20%.
SYMBOLS E2A
E2B
100
70
E2C
150
105
150
E2D
E2E
300
210
300
E2G
400
280
400
E2J
600
420
600
UNITS
Volts
Volts
Volts
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
VRRM
VRMS
VDC
50
35
50
200
140
200
Maximum DC Blocking Voltage
100
Maximum Average Forward Rectified Current,
at TL=120℃
Volts
2.0
Amps
Peak Forward Surge Current 8.3ms single half
sinewave superimposed on rated load(JEDEC method)
Maximum Instantaneous Forward Voltage at 1.0A
IFSM
VF
30.0
Amps
Volts
uA
0.95
1.25
1.7
Maximum DC Reverse Current TA=25O
5.0
100
35.0
10.0
35
C
IR
At Rated DC Blocking Voltage TA=100O
C
TRR
Cj
Maximum Reverse Recovery Time (Note 1)
Typical Junction capacitance (Note 2)
Typical Thermal Resistance (Note 3)
Operating and Storage Temperature Range
NOTES:
nS
pF
O
/W
C
RθJA
OC
TSTG
-55to +150
1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, Irr=0.25A
2. Measured at 1 MHz and Applied reverse voltage of 4.0 volts
3. 8.0mm2 (.013mm thick) land areas
http://www.yeashin.com
1
REV.02 20110725