SURFACE MOUNT
ELECTROLYTIC - 85˚C DVCR
Cylindrical leadless type for surface mounting
Low cost, general purpose, 2000 hours at 85°
New expanded CV Range
Anti-solvent (2 minutes)
Designed for automatic mounting and reflow soldering
SPECIFICATIONS
Item
Performance
Category Temperature Range (°C) –40 to +85
Tolerance of Rated Capacity (%)
Leakage Current (µA)
20
Less than 0.01CV or 3 whichever is larger (after 2min) C: rated capacitance (µF)
Tangent of Loss Angle (tan∂)
Rated Voltage (V)
tan∂ (max)
4
6.3
10
16
25
35
50
63 100
Ø3
0.42 0.30 0.24 0.22 0.16 0.14 0.12
0.42 0.28 0.24 0.20 0.14 0.12 0.10
–
–
–
–
Ø4 to Ø6.3
Ø8 to Ø10
–
4
7
0.28 0.24 0.20 0.14 0.12 0.10 0.10 0.10
Characteristics at high and low
temperatures
Rated Voltage (V)
6.3
4
10
3
16
2
25
2
35
2
50
2
63 100
Imped-
ance
Ø3
Z–25°C / Z+20°C
–
–
–
–
2
3
–
–
–
–
2
3
Z–40°C / Z+20°C 17
Ø4 to Ø6.3 Z–25°C / Z+20°C
Z–40°C / Z+20°C 15
10
3
8
6
4
3
3
7
3
2
2
2
2
8
5
4
3
3
3
Ø8 to Ø10 Z–25°C / Z+20°C
Z–40°C / Z+20°C
–
–
4
3
2
2
2
2
8
5
4
3
3
3
Endurance (85°C)
(Applied Ripple Current)
Test Time
2000 hours
The initial specified value or less
Within 20% of initial value (4wv 30%)
200% or less of the initial specified value (4wv: 3000%)
Leakage Current
Percentage of Capacitance Change
Tangent of Loss Angle
Shelf Life (85°C)
Test Time: 1000 hours: other items are the same as those for endurance. JIS C5101-1
JIS C5101-1, –18 1998 (IEC600384-1 1992, -18 1993)
Applicable Standards
COEFFICIENT OF FREQUENCY FOR RATED RIPPLE CURRENT
Frequency (Hz)/Rated Voltage
50-60
120
1k
10k - 100k
4 to 16
25 to 35
50 to 63
100
0.8
0.8
0.8
0.7
1
1
1
1
1.15
1.25
1.35
1.35
1.25
1.40
1.50
1.50
ORDERING INFORMATION
LF
DVCR
47
6.3
Range
Capacitance
µF
Voltage
Can Size
Lead Free
Small = Blank
D8 = 8mm dia
D10 = 10mm dia
73
www.dubilier.co.uk