Distributed Power Bulk Front-End
450-550 Watts 12V
Total Output Power:
450W - 550W
+12vdc Main Output +3.3vdc Stand-By Output
Wide Range Input Voltage: 90 - 264VAC
DS450-3/DS550-3
Distributed Power System
850 Watts 12V DPS
Electrical Specs
Input
Input Range
Frequency
Inrush Current
Efficiency
Conducted EMI
Radiated EMI
Power Factor
Leakage Current
Hold Up Time
90 - 264vac
47 - 63 Hz, single phase AC
15A Maximum
84% typical at full load, high line
FCC Subpart J EN55022 Class A
FCC Subpart J EN55022 Class A
0.99 typical
Special Features
1.30mA @ 240VAC
20ms Minimum
• Active Power Factor Correction
• EN61000-3-2 Harmonic Compliance
• Active AC Inrush Control
• 1U X 2U Form Factor
Output
Main DC Voltage
Stand-By
Adjustment Range
Regulation
+12v
+3.3vsb
• 10.3W / in3 (DS550)
8.4W / in3 (DS450)
• +12vdc Output
• +3.3vdc Stand-By
• No Minimum Load Required
• Hot Plug Operation
Factory Set, no pot adjustments
+12vdc; +5%/-3%
+3.3vsb; +5%/-4%
See Table 1 next page
+12vdc; 13.5 - 15vdc
+3.3vsb; 3.76 - 4.30vdc
+12vdc; 11.0 - 11.5vdc
+3.3vsb; 2.77 - 3.00vdc
1 Second max,
Over Current
Over Voltage
• N + 1 Redundant
• Internal OR'ing Fets
Under Voltage
• Active Current Sharing
• Built-in Cooling Fans (40mm x 28mm)
• I2C Communication Interface Bus
• EERPOM for FRU Data
• Amber LED Status, Fan_Fail
• Green LED Status, Power Good / AC_OK Status
• Internal Fan Speed Control
• Fan Fail Tach Output Signal
• One Year Warranty
Turn-On Delay
+12vOutput Rise Time
2 - 20mS, Monotonic
Logic Control
PS Inhibit
PS_Status
AC_Pfail
When supply is inserted into the system the pin is
pulled LOW and power supply is ON after all other pins
are seated
I2C port P6. When the power supply is on and running
normal P6 is low. When the power supply is off, either
due to -PS_ON, PS_KILL, or a fault, then P6 is high.
I2C port P7. P7 is high except when the power supply
turns the main outputs, not +3.3VSB, off due to an AC
failure (AC missing or too low for power supply
operation). If the supply is turned off due to -PS_ON,
PS_KILL, or a fault, then P7 remains high.
The PSU will provides an open collector Tach 1 output.
This signal is generated from the fan. The signal
should generate 2 pulses per revolution. The logic in
the system will be operating at 3.3V.
Environmental
Operating Temperature: -10°C to 50°C
(50% power derating at 70°C)
Fan_Fault
Tach_1
Storage Temperature: -40° to +70°C
Altitude, Operating 10,000ft
Electromagnetic Susceptibility / Input Transients:
-EN61000-3-2, -3-3
-EN61000-4-2, 4-4, -4-5, 4-11 Level
-EN55024:1998
Safety
Humidity: 20 to 90% RH, non-condensing
Shock and Vibration Specification
(Complies with Astec Std Specification, Q3205
MTBF (Demonstrated): 400KHrs at full load, 40°C
UL/cUL 60950 (UL Recognized)
NEMKO+ CB Report EN60950
EN60950
CE Mark
China CCC
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
Rev 6.20.07