80-240 Watts
xppower.com
DRS80-240 Series
•
•
•
•
•
•
•
Ultra Slim Cases
150% Peak Load for 4 seconds
Wide Output Adjustment Range
High Efficiency – Up to 92%
12 V, 24 V & 48 V Versions
Low Output Ripple & Noise
-20 ºC to 70 ºC Operating Temperature
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 85-264 VAC
• 47-63 Hz
Efficiency
Isolation
• See table
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• 80 W: 2 A at 85 VAC
120 W: 2 A at 85 VAC
240 W: 4 A at 85 VAC
Switching Frequency
• DRS80 60-300 kHz variable
Inrush Current
Power Factor
• 30 A max at 230 VAC
DRS120 & DRS240 100 kHz typical PFC
& main converter
• DRS80 0.6 typical
DRS120 & 240 0.95 typical
Conforms to EN61000-3-2 Class A.
Signals
MTBF
• DRS120 & 240: DC OK Volt free contacts
• >200 kHrs to MIL HDBK217F
Earth Leakage Current • 1.5 mA maximum
Environmental
Output
Operating Temperature • -20 ºC to +70 ºC (see derating curves)
Output Voltage
• See table
• See table
Cooling
• Natural covection
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Operating Humidity
Storage Temperature
Shock
• 5-95ꢀ RH, non-condensing
• -25 °C to +85 °C
•
1ꢀ at 50ꢀ load
• No minimum load required
• 1 s maximum
• IEC68-2-6, 30 g, 11ms half sine, 3 times in
each of 6 axes
Start Up Delay
Start Up Rise Time
Hold Up Time
• 20 ms typical
Vibration
• IEC68-2-27, 10-500 Hz, 2 g 10
mins/sweep. 60 mins for each of 3 axes
• 20 ms minimum at full load and 115 VAC
Line Regulation
Load Regulation
Transient Response
•
•
0.5ꢀ
1ꢀ
EMC & Safety
Emissions
• EN55022, class B conducted & radiated
• EN61000-3-2, class A
• 10ꢀ maximum deviation, recovering to
less than 1ꢀ within 500 µs for 50ꢀ step
load change at 0.2 A/µs
Harmonic Currents
Voltage Flicker
ESD Immunity
• EN61000-3-3
Ripple & Noise
• 100 mV pk-pk maximum, measured with
20 MHz BW
• EN61000-4-2, 4 KV Contact,
8 KV Air Discharge
Overvoltage Protection • 12 V output: 16.5-18 V, 24 V output:
Radiated Immunity
EFT/Burst
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
29-31.2 V, 48 V output: 57.6-62.4 V
Overload Protection
• 110-150ꢀ of rated current, constant
current limit
Surge
• EN61000-4-5, Installation Class 3
Perf Criteria B
Short Circuit Protection • Trip and restart (hiccup mode)
Conducted Immunity
Dips & Interruptions
• EN61000-4-6, 3 V Perf Criteria A
Temperature
Coefficient
•
0.02ꢀ/°C
• EN61000-4-11, 30ꢀ 10 ms,
60ꢀ 100 ms, 100ꢀ 5000 ms
Perf Criteria A, B, B
Safety Approvals
• UL508, EN60950, UL1604 Pending