Axial Lead Reed Switches
High Power > DRS-DTH
RoHS
DRS-DTH 39.7mm Standard Changeover Reed Switch
Description
The DRS-DTH Reed Switch is a large changeover switch with a
39.67mm long x 5.33mm diameter (1.562” x 0.210”) glass
envelope, capable high voltage and power switching up to 500Vdc
at 2mA, or 0.5A up to 30W/VA. The DRS-DTH has an insulation
resistance of 109 ohms minimum and contact resistance of less
than 125 milli-ohms.
Features
Agency Approvals
• Changeover switch
• Minimum voltage breakdown
1200Vdc
Agency
Agency File Number
Ampere-Turns Range
• Capable of switching 500Vdc
or 0.5A at up to 30W
E47258
E471070
50-80 AT
• Available sensitivity range
50-80 AT
Note: Contact Littelfuse for specific agency approval ratings.
Dimensions
Benefits
Dimensions in mm (inch)
• Hermetically sealed switch
contacts are not affected by
and have no effect on their
external environment
• Capable of switching
European mains voltage
1.83
(.072) NOM.
0.25
(.010) NOM.
• Zero operating power
required for contact closure
1.27
(.050) DIA. REF.
CL OF OVERLAP
(.218) MAX.
5.54
27.66
(1.89) REF.
• Can be used as changeover
or normally closed contact
5.33
(.210) MAX.
1.02
(.040) DIA. REF.
25.40
12.45
(1.000) NOM.
(.490) NOM.
38.10 - 39.67
(1.500) NOM. - (1.562) MAX.
85.73 - 84.14
(3.375) NOM. - (3.3125) MIN.
SwitchType
Applications
• Security
• Limit switching
• Industrial safety applications
• White goods applications
Contact Form
Materials
C (SPDT-CO)
Body: Glass
Leads:Tin-plated Ni-Fe wire
Note: SPDT-CO = Single-Pole, Double-Throw, Change Over
Electrical Ratings
Contact Rating 1
-
W/VA - max.
Vdc - max.
Vac - max.
Vdc - min.
Adc - max.
Aac - max.
Adc - max.
Ω - max.
30
500
350
1200
0.50
0.35
3.0
Switching 2
Breakdown 4
Voltage 3
Current 3
Switching 2
Carry
0.125
109
Contact, Initial Insulation
Resistance
Capacitance
Temperature
Notes:
Ω - min.
Contact
Operating
Storage 5
pF - typ.
2.0
-20 to +125
-65 to +125
°C
1. Contact rating - Product of the switching voltage and current should never exceed the wattage rating. Contact Littelfuse for additional load/life information.
2. When switching inductive and/or capacitive loads, the effects of transient voltages and/or currents should be considered. Refer to Application Notes AN108A and AN107 for details.
3. Electrical Load Life Expectancy - Contact Littelfuse with voltage, current values along with type of load.
4. Breakdown Voltage - per MIL-STD-202, Method 301.
5. Storage Temperature - Long time exposure at elevated temperature may degrade solderability of the leads.
© 2020 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: BO/12/08/20