DRQ Series
Dual Winding, Shielded Inductors/Transformer
• Peak current ratings from 0.13 amps to 56 amps
• RMS current ratings from 0.128 amps to 17.9 amps
• Inductance ratings from 0.33µH to 4.02mH
• Surface Mount
• 200Vac Isolation between windings
• Ferrite core material
Applications
• As a transformer: SEPIC, flyback
• As an inductor: buck, boost, coupled inductor
• DC-DC converters
• VRM inductor for CPU and DDR power supplies
• Input and output filter chokes
Environmental Data
• Storage temperature: -40°C to +125°C
• Operating temperature: -40°C to +125°C (range is application
specific).
Description
• 125°C maximum total operating temperature
• Dual winding inductors that can be used as either
a single inductor, or in coupled inductor/transformer applications
(1:1 turns ratio)
• Four sizes of shielded drum core inductors
• Windings can be connected in series or parallel, offering a broad
range of inductance and current ratings
• Solder reflow temperature: 260°C max. for 10 seconds max.
Packaging
• Supplied in tape and reel packaging, 1350 (DRQ73),
1100 (DRQ74), 600 (DRQ125), and 350 (DRQ127) per reel
Parallel Ratings
Series Ratings
(1)
(2)
(3)
(5)
(1)
(2)
(3)
(5)
Part Number
Rated
OCL
I
I
DCR Ω (4)
Volt
OCL
I
I
sat
DCR Ω (4)
Volt
rms
sat
rms
Inductance +/-20%
Amps
Amps
Peak
typ.
µ-Sec
+/-20%
(µH)
Amps
Amps
Peak
typ.
µ-Sec
(µH)
0.33
1.00
1.50
2.20
3.30
4.70
6.80
8.20
10.0
15.0
22.0
33.0
47.0
68.0
82.0
100
(µH)
DRQ73-R33-R
DRQ73-1R0-R
DRQ73-1R5-R
DRQ73-2R2-R
DRQ73-3R3-R
DRQ73-4R7-R
DRQ73-6R8-R
DRQ73-8R2-R
DRQ73-100-R
DRQ73-150-R
DRQ73-220-R
DRQ73-330-R
DRQ73-470-R
DRQ73-680-R
DRQ73-820-R
DRQ73-101-R
0.306
0.992
1.482
2.070
3.540
4.422
6.480
8.930
10.30
15.01
22.65
34.41
48.62
68.91
80.37
101.4
6.19
5.25
4.64
4.11
3.31
3.09
2.55
2.19
2.08
1.83
1.62
1.31
1.08
0.89
0.86
0.73
14.4
7.97
6.52
5.52
4.22
3.78
3.12
2.66
2.47
2.05
1.67
1.35
1.14
0.96
0.89
0.79
0.0074
0.0103
0.0132
0.0167
0.0259
0.0297
0.0435
0.0592
0.0656
0.0844
0.107
1.98
3.56
4.36
5.15
6.73
7.52
9.11
10.7
11.5
13.9
17.0
21.0
24.9
29.7
32.1
36.0
1.224
3.968
5.928
8.280
14.16
17.69
25.92
35.72
41.20
60.04
90.60
137.6
194.5
275.6
321.5
405.6
3.10
2.63
2.32
2.06
1.66
1.55
1.28
1.10
1.04
0.916
0.811
0.653
0.542
0.444
0.430
0.367
7.18
3.99
3.26
2.76
2.11
1.89
1.56
1.33
1.24
1.03
0.83
0.68
0.57
0.48
0.44
0.39
0.0296
0.0411
0.0527
0.0669
0.1035
0.1188
0.1742
0.2368
0.2623
0.339
0.429
0.665
0.965
1.43
3.96
7.12
8.72
10.3
13.5
15.0
18.2
21.4
23.0
27.8
34.0
42.0
49.8
59.4
64.2
72.0
0.166
0.241
0.358
0.384
1.54
2.11
0.527
1) Open Circuit Inductance Test Parameters: 100kHz, 0.25 V , 0.0 Adc
rms
6) Turns Ratio (1:3):(2-4) 1:1
Parallel: (1,2 -4,3) Series: (1-4) tie (2-3)
7) Part number definition: DRQxxx-yyy-R
DRQxxx = product code and size,
-yyy = inductance value in µH,
2) RMS current for an approximate ∆T of 40°C without core loss. It is recommended that the
temperature of the part not exceed 125°C.
3) Peak current for approximately 30% roll-off at 20°C
4) DCR limits @ 20°C
R = decimal point. If no R is present, third character = # of zeros
-R suffix = RoHS compliant
5) Applied Volt-Time product (V-µS) across the inductor. This value represents the applied V-µS
at 100KHz necessary to generate a core loss equal to 10% of the total losses for a 40°C
temperature rise.
1207 BU-SB07326