DRQ-12/42-D48 Series
www.murata-ps.com
500W Digital Fully Regulated
Intermediate DC-DC Bus Converter
PRODUCT OVERVIEW
Typical unit
The DRQ 500W series provides a fully regulated, rated at 2250 Vdc for functional insulation. Target
digitally controlled DC output in a ¼-brick format
that will support the evolving Advanced Bus Con-
verter (ABC) industry standard footprint for isolated
board mounted power modules. The DRQ series
markets include networking equipment, Power over
Ethernet applications, wireless networking equip-
ment, telecommunications equipment, wireless
pre-amplifiers, industrial and test equipment, and
supports advances in power conversion technology applications requiring a regulated 11.5V output.
including a digital interface supporting the PMBus
protocol for communications to power modules.
The DRQ series offers high output current (up to
43.5 Amps) in an industry standard “quarter brick”
p
ackage. The DRQ series is an isolated, regulated,
500W-11.5Vout quarter brick that supports the
TNV input voltage range of 38V-75V with a typical
efficiency of 95.5%.
A wealth of self-protection features include input
undervoltage lockout and overtemperature shut-
down; over current protection using the “hiccup”
autorestart technique provides indefinite short-
circuit protection, along with output OVP. The DRQ
series is certified to safety standards UL/IEC/CSA
60950-1, 2nd edition. It meets RFI/EMI conducted
emission compliance to EN55022, CISPR22 with an
external filter.
FEATURES
Fixed DC outputs, 11.5V @43.5A
Advanced Bus Converter industry standard
quarter-brick with digital PMBus™ interface
Advanced automated surface mount assembly
and planar magnetics deliver galvanic isolation
Optional five pin version (DOSA compatible
pinouts)
38 to 75 Volt DC input range (48 VDC nominal)
Remote ON/Off enable control
High efficiency (95.5%)
Stable no-load operation
APPLICATIONS
Monotonic startup into pre-bias output condition
Embedded systems, datacom and telecom
installations, wireless base stations
Instrumentation systems, R&D platforms, auto-
mated test fixtures
Certified to UL 60950-1, CSA-C22.2 No. 60950-
1, 2nd edition safety approvals
Extensive self-protection, OVP, input undervolt-
age, current limiting and thermal shutdown
Disk farms, data centers and cellular repeater sites
Data concentrators, voice forwarding and
Remote sensor systems, dedicated controllers
speech processing systems
F1
+Vin (1)
+Vout (8)
Barrier
External
DC
Power
Source
On/Off
Control
(2)
Controller
and Power
Open = On
Reference and
Error Amplifier
logic)
-Vin (3)
-Vout (4)
Figure 1. Connection Diagram (without digital interface)
Typical topology is shown. Murata Power Solutions recommends an external fuse.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_DRQ-12/42-D48.A03 Page 1 of 24