DR7001-EV
• Designed for Short-Range Wireless Data Communications
• Supports RF Data Transmission Rates Up to 115.2 kbps
• 3 V, Low Current Operation plus Sleep Mode
• Up to 10 mW Transmitter Power
315.00 MHz
Transceiver
Evaluation
Module
The DR7001-EV hybrid transceiver module is ideal for short-range wireless data applications where robust
operation, small size, low power consumption and low cost are required. The DR7001-EV utilizes RFM’s
TR7001 amplifier-sequenced hybrid (ASH) architecture to achieve this unique blend of characteristics. All
critical RF functions are contained in the hybrid, simplifying and speeding design-in. The receiver section of
the DR7001-EV is sensitive and stable. A wide dynamic range log detector, in combination with digital AGC
and a compound data slicer, provide robust performance in the presence of on-channel interference or noise.
Two stages of SAW filtering provide excellent receiver out-of-band rejection. The transmitter includes
provisions for both on-off keyed (OOK) and amplitude-shift keyed (ASK) modulation. The transmitter employs
SAW filtering to suppress output harmonics, facilitating compliance with FCC and similar regulations.
Absolute Maximum Ratings
Rating
Value
-0.3 to +4.0
-50 to +100
260
Units
V
Power Supply and All Input/Output Pins
Non-Operating Case Temperature
Soldering Temperature (10 seconds, 5 cycles maximum)
°C
°C
Electrical Characteristics
Characteristic
Sym
Notes
Minimum
Typical
Maximum
Units
f
Operating Frequency
314.800
315.200
MHz
o
Data Modulation Type
OOK/ASK
OOK Data Rate
30
kb/s
kb/s
ASK Data Rate
115.2
Receiver Performance (OOK @ 4.8kbps)
Sensitivity, 4.8 kbps, 10-3 BER, AM Test Method
Input Current, 4.8 kbps, 3.0V Supply
Sensitivity, 19.2 kbps, 10-3 BER, AM Test Method
Input Current, 19.2 kbps, 3.0V Supply
Transmitter Performance (OOK @ 4.8kbps)
Peak RF Output Power, 235 µA TXMOD Current
Peak Current, 235 µA TXMOD Current
OOK Turn On/Turn Off Times
-108
4.2
dBm
mA
-104
4.25
dBm
mA
P
10
32
dBm
mA
OL
I
TPL
t
/t
12/6
1.1/1.1
3.7
µs
ON OFF
t
/t
ASK Output Rise/Fall Times
µs
TR TF
Power Supply Voltage Range (including I/O)
Operating Ambient Temperature
Power Supply Voltage Ripple
Vcc
2.2
-40
Vdc
°C
T
+85
A
10
mVp-p
www.RFM.com
E-mail: info@rfm.com
Page 1 of 8
©2008 by RF Monolithics, Inc.
DR7001-EV - 4/8/08