5秒后页面跳转
DR2220D35URJ PDF预览

DR2220D35URJ

更新时间: 2024-09-14 00:46:19
品牌 Logo 应用领域
快达 - CRYDOM /
页数 文件大小 规格书
2页 790K
描述
DIN Rail Mount

DR2220D35URJ 数据手册

 浏览型号DR2220D35URJ的Datasheet PDF文件第2页 
InstallationDISN RhaileMeoutnt  
PART NUMBER NOMENCLATURE  
Rated Load Current  
20: 20 Amps  
Switching Type  
30: 30 Amps  
Blank: Zero Voltage Turn-On  
R: Instantaneous Turn-On  
(AC Output only)  
Operating Voltage  
20: 1-200 VDC  
60: 48-600 VAC  
35: 35 Amps [High I2t]  
(AC Output only)  
DR22 Series Solid State Relays  
Series  
Crydom DR22 Series Solid State Relays were developed to offer the advantages of  
semiconductor switching technology in a standard 22.5 mm industrial package. Quick and easy  
installation is coupled with low drive power requirements and efficient, reliable power SCR  
output. This compact new design offers up to 35 ARMS in ambient temperatures of 40ºC.  
DR22  
60  
A
20  
V  
R
J
Control Voltage  
Terminal Layout  
Input Connector  
A: 90-280 VAC/VDC  
(AC Output only)  
D: 4-32 VDC  
U: Relay Configuration  
V: Contactor  
Blank: Screw Terminal  
J: Spring Terminal  
(V and W suffixes only)  
Be sure to visit the product series datasheet available at the Crydom website to complement this  
information. If you have questions or need additional information please contact Crydom Tech  
Support.  
Configuration  
AC  
Output  
only  
(std. screw)  
W: Contactor  
Configuration  
(elevator screw)  
Please read all instructions before using your DIN Rail Mount Solid State Relay (SSR).  
Required for valid part number  
For options only and not required for valid part number  
MOUNTING INSTRUCTIONS  
Install the relay on the DIN Rail (as shown in fig. 1)  
To install  
on DIN rail  
WIRING DIAGRAMS  
Maximum recommended terminal screw torque input  
terminal:  
Relay AC  
Contactor AC  
Relay DC (A)  
To remove  
from DIN rail  
(-  
/
)
(
-
)
(+ /  
)
(+)  
Contactor configuration (”V” & “W” suffixes):  
5 in-lb (0.5 Nm)  
V
AC  
Relay configuration (”U” suffix):  
13-15 in-lb (1.5-1.7 Nm)  
1/L1  
+3/A1  
-4/A2  
+3/A1  
-4/A2  
Maximum recommended terminal screw torque load  
fig. 1 SSR mounted on DIN rail  
(-/ )  
)
(+ /  
terminal:  
INPUT  
STATUS  
INPUT  
STATUS  
Contactor configuration (”V” & “W” suffixes): 18-20 in-lb (2.0-2.2 Nm)  
Relay configuration (”U” suffix): 13-15 in-lb (1.5-1.7 Nm)  
INPUT  
STATUS  
+3/A1 -4/A2  
Load  
If multiple units are installed be sure to follow derating curves  
Recommended wire sizes as shown in TABLE 1  
WARNING! Removing product from 35 mm rail incorrectly by not using the appropriate tool  
1/L1  
2/T1  
+1  
-2  
would damage the latching system.  
2/T1  
+
AC  
V
TABLE 1. Recommended Wire Sizes  
+
V
-
Load  
(B)  
Load  
Terminal  
Configuration  
Wire Size  
(Solid / Stranded)  
Wire Pull-Out  
Strength (lb)[N]*  
2
2 x 18 AWG (1 mm ) Stranded [minimum]  
20 [88]  
60 [266]  
20 [88]  
40 [177]  
25 [111]  
80 [355]  
90 [400]  
4.5 [20]  
30 [133]  
5 [22]  
Output  
Relay “U” suffix  
Important Considerations  
Be sure to use input and output voltages within  
2
2 x 10 AWG (6 mm ) Stranded [maximum]  
0.89 in [22.5 mm]  
Minimum  
2
operating ranges.  
2 x 18 AWG (1 mm ) Stranded  
Input  
Relay “U” suffix  
LED indicates only input status. It does not  
represent output status.  
To achieve maximum ratings, there must be a  
minimum spacing of 0.89 in (22.5 mm) between the  
devices in free air (as shown in fig.2).  
2
2 x 12 AWG (4 mm ) Stranded  
2
Output  
Contactor  
“V” &“W”  
suffixes  
2 x 20 AWG (0.75 mm ) [minimum]  
2
2 x 10 AWG (6 mm )  
2
2 x 8 AWG (10 mm ) [maximum]  
Protective Earth (PE) screw type recommended is  
10-32 UNC standard, not provided with SSR. Through  
the use of a DIN rail ground (protective conductor)  
terminal block, the DIN rail itself can be used as the  
grounding bus bar. In this case, the zinc plated steel  
material used for the DIN rail clip of DR22 models,  
permits a secure path to ground and avoid the need of  
a further PE connection (see fig.3).  
2
30 AWG (0.05 mm ) [minimum]  
Input  
Screw  
Spring  
2
12 AWG (3.3 mm ) [maximum]  
Contactor  
“V” &“W”  
suffixes  
fig. 2 Multiple units  
mounting  
for maximum  
ratings  
2
26 AWG (0.13 mm ) [minimum]  
fig. 3 DR22 model  
with Protective  
Earth screw  
2
12 AWG (3.3 mm ) [maximum]  
5 [22]  
* Tests performed on Stranded wire  
TABLE 3. Recommended Accessories  
TABLE 2. Compatible Terminals  
W
D
W D  
Terminals  
Fork Lug  
Ring Lug  
Copper Lug  
Copper Lug  
Connectors  
ID Marker  
Lug Terminal  
Crydom Part No.  
TRM0  
TRM6  
CP201  
CP202  
CNLB  
CNLN  
CNL2  
TRM0  
TRM6  
Width [W] in (mm)  
Stud Size Dia [D] (in)  
Wire Size AWG  
0.45 (11.4)  
#8 (0.168)  
0.45 (11.4)  
#8 (0.168)  
6-0  
14-6  
General Notes  
(A) Load can be wired to either terminal 1 or terminal 2. Proper polarity must be observed for the DC control power supply, with terminal 3 being positive with respect to terminal 4.  
(B) DC inductive loads must be diode suppressed.  
(C) AC input models operating range is -20 to 60 ºC  
Rev. 060816  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  

与DR2220D35URJ相关器件

型号 品牌 获取价格 描述 数据表
DR2220D35VRJ CRYDOM

获取价格

DIN Rail Mount
DR2220D35WRJ CRYDOM

获取价格

DIN Rail Mount
DR2260A20U ETC

获取价格

RELAY SSR 600V 20A DIN RAIL
DR2260A20UR ETC

获取价格

RELAY SSR 600V 20A DIN RAIL
DR2260A20URJ CRYDOM

获取价格

DIN Rail Mount
DR2260A20VJ ETC

获取价格

RELAY SSR 600V 20A DIN RAIL
DR2260A20VR ETC

获取价格

RELAY SSR 600V 20A DIN RAIL
DR2260A20VRJ CRYDOM

获取价格

DIN Rail Mount
DR2260A20W ETC

获取价格

RELAY SSR 600V 20A DIN RAIL
DR2260A20WJ ETC

获取价格

RELAY SSR 600V 20A DIN RAIL