DIN Rail Mount
Datasheet
DR22 Series
• Output ratings up to 30 Amps at 200 VDC
DC Output DIN Rail Mount SSRs
• Integral heat sink eliminates the need for complex thermal calculations
• DBC substrate for superior thermal performance
• LED input status indicator
• IP20 touch-safe housing
• 1kHz Maximum PWM Frequency
• 3750 VAC optical isolation
• C-UL-US approved
PRODUCT SELECTION
Control Voltage
4-32 VDC
20 A
DR2220D20U
30 A
DR2220D30U
AVAILABLE OPTIONS
Rated Load Current
20: 20 Amps
30: 30 Amps
Operating Voltage
20: 1-200 VDC
Series
DR22
20
D
20
U
Control Voltage
Terminal Layout
U: Relay Configuration
D: 4-32 VDC
Required for valid part number
OUTPUT SPECIFICATIONS (1)
Description
Absolute Maximum Rating [VDC]
Recommended Operating Voltage [VDC]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Load Current, DC General Use UL508 @ 40°C [ADC]
Load Current, DC Motor Starting UL508 FLA @ 40°C [ADC]
Minimum Load Current [mA] (2)
20 A
200
1-150
0.1
20
4.1
30 A
200
1-150
0.2
30
5.4
5
5
Maximum Surge Current [ADC] (10ms)
58
86
Maximum On-State Voltage Drop @ Rated Current [VDC]
Maximum On-State Resistance [RDS-ON][Ohms]
Maximum Pulse Width Modulation Frequency [Hz] (3)
Motor Rating UL 508 [HP (kW)]: 120 VDC
0.680
0.034
1000
1/3 (0.25)
0.480
0.016
900
1/2 (0.37)
(1)
INPUT SPECIFICATIONS
Description
DC Control
4-32 VDC
-32 VDC
4 VDC
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage (4)
Must Turn-Off Voltage
1 VDC
Minimum Input Current (for on-state)
Maximum Input Current
11 mA
15 mA
Nominal Input Impedance
Maximum Turn-On Time [µsec]
Maximum Turn-Off Time [µsec]
Current Regulated
75
100
Do not forget to visit us at: www.crydom.com